FireCADCalc

Wind Turbine Gravity Foundation: Overturning and Bearing Pressure

Eccentricity, overturning safety factor and maximum soil bearing pressure of a square gravity foundation under the turbine weight, overturning moment and base shear.

Thermal power plant

Inputs

Examples: Illustrative 18 m base, 80 MN mGapping case 15 m base, 100 MN mSmall 6 m base, 2 MN m

Accepted: 2 to 50 m
Accepted: 0.5 to 6 m
Accepted: 10 to 100,000 kN
Accepted: 10 to 30 kN/m³
Accepted: 0 to 10,000,000 kN·m
Accepted: 0 to 100,000 kN

Results

Rigid square base, moment about one axis: within the middle third (e ≤ B/6) pressure is trapezoidal, q = (W/B²)(1 + 6e/B); beyond it the base lifts and q = 2W/[3B(B/2 − e)]. Design standards also check sliding, soil stiffness for tower frequency, fatigue and buoyancy with groundwater.

Total vertical load15,875kN
Moment at the foundation base102,250kN·m
Eccentricity M_b/W6.4409m
Safety factor against overturning W·B/2/M_b1.1644
Maximum bearing pressure666.21kPa
Fraction of base in contact21.181%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 18 m base, 80 MN m. The inputs, in the units selected above:

InputValue
Foundation width (square)18.000 m
Foundation depth2.5000 m
Turbine and tower weight4,000.0 kN
Unit weight of foundation and backfill22.000 kN/m³
Overturning moment at tower base80,000 kN·m
Base shear800.00 kN

Applying the formula below gives:

ResultValue
Total vertical load21,820 kN
Moment at the foundation base82,000 kN·m
Eccentricity M_b/W3.7580 m
Safety factor against overturning W·B/2/M_b2.3949
Maximum bearing pressure154.17 kPa
Fraction of base in contact87.366 %

Open this example in the calculator and change any input.

Formula

\(e = \frac{M + Vt}{W}, \quad q_{max} = \frac{W}{B^2}\left(1 + \frac{6e}{B}\right)\;(e \le B/6), \quad q_{max} = \frac{2W}{3B(B/2 - e)}\;(e > B/6)\)

Variables

Symbol Meaning SI unit
\(B\) Foundation width (square) m
\(t\) Foundation depth m
\(W_t\) Turbine and tower weight N
\(\gamma\) Unit weight of foundation and backfill N/m³
\(M\) Overturning moment at tower base N·m
\(V\) Base shear N
\(W\) Total vertical load N
\(M_b\) Moment at the foundation base N·m
\(e\) Eccentricity M_b/W m
\(FS\) Safety factor against overturning W·B/2/M_b -
\(q_{max}\) Maximum bearing pressure Pa
\(A'/A\) Fraction of base in contact -

Method and standards

Eccentric footing.

Where it is used

  • Onshore turbine foundation sizing.
  • Checks of mast and chimney bases.

Common mistakes

  • Forgetting the shear moment arm to the base.
  • Ignoring buoyancy when groundwater is high.

Assumptions and limits

  • Rigid square footing; uniaxial moment; no buoyancy.

References

  • Rigid-footing eccentric loading

Questions and answers

Why are wind turbine foundations so large?

The huge overturning moment must be resisted by weight and width; 18–25 m wide bases of 2–3 m depth are common onshore.

What is gapping?

When the eccentricity exceeds B/6 part of the base lifts off the soil; many guidelines allow none under normal operating loads.

What do the defaults represent?

An illustrative 18 m square, 2.5 m deep base under a 4,000 kN turbine, an 80,000 kN·m base moment and 800 kN shear (a case that just lifts part of the base).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.