Worked example
Example: Illustrative 18 m base, 80 MN m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Foundation width (square) | 18.000 m |
| Foundation depth | 2.5000 m |
| Turbine and tower weight | 4,000.0 kN |
| Unit weight of foundation and backfill | 22.000 kN/m³ |
| Overturning moment at tower base | 80,000 kN·m |
| Base shear | 800.00 kN |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total vertical load | 21,820 kN |
| Moment at the foundation base | 82,000 kN·m |
| Eccentricity M_b/W | 3.7580 m |
| Safety factor against overturning W·B/2/M_b | 2.3949 |
| Maximum bearing pressure | 154.17 kPa |
| Fraction of base in contact | 87.366 % |
Open this example in the calculator and change any input.
Formula
\(e = \frac{M + Vt}{W}, \quad q_{max} = \frac{W}{B^2}\left(1 + \frac{6e}{B}\right)\;(e \le B/6), \quad q_{max} = \frac{2W}{3B(B/2 - e)}\;(e > B/6)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(B\) | Foundation width (square) | m |
| \(t\) | Foundation depth | m |
| \(W_t\) | Turbine and tower weight | N |
| \(\gamma\) | Unit weight of foundation and backfill | N/m³ |
| \(M\) | Overturning moment at tower base | N·m |
| \(V\) | Base shear | N |
| \(W\) | Total vertical load | N |
| \(M_b\) | Moment at the foundation base | N·m |
| \(e\) | Eccentricity M_b/W | m |
| \(FS\) | Safety factor against overturning W·B/2/M_b | - |
| \(q_{max}\) | Maximum bearing pressure | Pa |
| \(A'/A\) | Fraction of base in contact | - |
Method and standards
Eccentric footing.
Where it is used
- Onshore turbine foundation sizing.
- Checks of mast and chimney bases.
Common mistakes
- Forgetting the shear moment arm to the base.
- Ignoring buoyancy when groundwater is high.
Assumptions and limits
- Rigid square footing; uniaxial moment; no buoyancy.
References
- Rigid-footing eccentric loading
Questions and answers
Why are wind turbine foundations so large?
The huge overturning moment must be resisted by weight and width; 18–25 m wide bases of 2–3 m depth are common onshore.
What is gapping?
When the eccentricity exceeds B/6 part of the base lifts off the soil; many guidelines allow none under normal operating loads.
What do the defaults represent?
An illustrative 18 m square, 2.5 m deep base under a 4,000 kN turbine, an 80,000 kN·m base moment and 800 kN shear (a case that just lifts part of the base).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 7