FireCADCalc

Wind Turbine Tower Base Moment from Rotor Thrust and Tower Drag

Overturning moment and shear at the tower base from rotor thrust at hub height and wind drag on the tower with a power-law wind profile.

Thermal power plant

Inputs

Examples: Illustrative 600 kN thrust, 100 m tower, 12 m/sParked storm 50 m/s, small thrustSmall 30 m tower 1 m, 14 m/s

Accepted: 0 to 100,000 kN
Accepted: 5 to 200 m
Accepted: 0.2 to 12 m
Accepted: 0.3 to 1.5
Accepted: 1 to 80 m/s
Accepted: 0 to 0.5
Accepted: 0.5 to 1.5 kg/m³

Results

Tower drag ∫½ρC_dD U(z)² dz with U = U_h(z/H)^α gives F = qH/(2α + 1) and M = qH²/(2α + 2), q = ½ρC_dDU_h². Design loads add gusts, dynamics and safety factors; the parked extreme-wind case often governs.

Drag on the tower1.5435kN
Base shear16.544kN
Moment from tower drag27.011kN·m
Moment from rotor thrust450.00kN·m
Total base overturning moment477.01kN·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 600 kN thrust, 100 m tower, 12 m/s. The inputs, in the units selected above:

InputValue
Rotor thrust600.00 kN
Hub height100.00 m
Mean tower diameter4.5000 m
Tower drag coefficient0.60000 -
Wind speed at hub height12.000 m/s
Wind shear exponent0.14000 -
Air density1.2250 kg/m³

Applying the formula below gives:

ResultValue
Drag on the tower18.605 kN
Base shear618.60 kN
Moment from tower drag1,044.5 kN·m
Moment from rotor thrust60,000 kN·m
Total base overturning moment61,044 kN·m

Open this example in the calculator and change any input.

Formula

\(F_t = \frac{qH}{2\alpha + 1}, \quad M = TH + \frac{qH^2}{2\alpha + 2}, \quad q = \frac{1}{2}\rho C_dD_tU_h^2\)

Variables

Symbol Meaning SI unit
\(T\) Rotor thrust N
\(H\) Hub height m
\(D_t\) Mean tower diameter m
\(C_d\) Tower drag coefficient -
\(U_h\) Wind speed at hub height m/s
\(\alpha\) Wind shear exponent -
\(\rho\) Air density kg/m³
\(F_t\) Drag on the tower N
\(V\) Base shear N
\(M_t\) Moment from tower drag N·m
\(M_r\) Moment from rotor thrust N·m
\(M\) Total base overturning moment N·m

Method and standards

Tower base loads.

Where it is used

  • Foundation and tower preliminary design.
  • Load checks for retrofits.

Common mistakes

  • Ignoring tower drag in parked storm cases.
  • Applying hub wind speed over the whole tower height.

Assumptions and limits

  • Steady loads; uniform tower diameter.

References

  • Rotor thrust and tower drag with a power-law profile

Questions and answers

Which load dominates the base moment?

Rotor thrust at hub height, usually well over 80 % of the operating base moment; tower drag matters much more for parked turbines in storms.

Why is the tower moment arm about half the height?

Drag is spread up the tower and grows with height through the wind profile, so its resultant sits slightly above mid-height.

What do the defaults represent?

An illustrative 600 kN rotor thrust on a 100 m tower of 4.5 m mean diameter in a 12 m/s hub wind, shear exponent 0.14.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.