FireCADCalc

Power Coefficient from a Measured Power Curve Point

Electrical and rotor power coefficients of a wind turbine from a measured power at a wind speed, with the air density, rotor size and drive-train efficiency.

Thermal power plant

Inputs

Examples: Illustrative 1.65 MW at 8 m/s, 120 mRated region 3.5 MW at 12 m/sSmall 10 kW at 10 m/s, 7 m

Accepted: 1 to 40 m/s
Accepted: 0.001 to 20,000 kW
Accepted: 1 to 300 m
Accepted: 0.5 to 1.5 kg/m³
Accepted: 50 to 100 %

Results

C_P,e = P/(½ρAV³); rotor C_P = C_P,e/η. Modern turbines reach electrical C_P of about 0.45–0.48 at their best wind speed.

Power in the wind11,970kW
Electrical power coefficient0.29239
Rotor power coefficient0.31106
Fraction of the Betz limit52.491%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.65 MW at 8 m/s, 120 m. The inputs, in the units selected above:

InputValue
Wind speed (hub height, density-normalised)8.0000 m/s
Measured electrical power1,650.0 kW
Rotor diameter120.00 m
Air density1.2250 kg/m³
Drive-train and generator efficiency94.000 %

Applying the formula below gives:

ResultValue
Power in the wind3,546.7 kW
Electrical power coefficient0.46522
Rotor power coefficient0.49491
Fraction of the Betz limit83.516 %

Open this example in the calculator and change any input.

Formula

\(C_{P,e} = \frac{P}{\frac{1}{2}\rho AV^3}, \quad C_{P,r} = \frac{C_{P,e}}{\eta}\)

Variables

Symbol Meaning SI unit
\(V\) Wind speed (hub height, density-normalised) m/s
\(P\) Measured electrical power W
\(D\) Rotor diameter m
\(\rho\) Air density kg/m³
\(\eta\) Drive-train and generator efficiency -
\(P_w\) Power in the wind W
\(C_{P,e}\) Electrical power coefficient -
\(C_{P,r}\) Rotor power coefficient -
\(C_{P,r}/C_{Betz}\) Fraction of the Betz limit -

Method and standards

Power coefficient from data.

Where it is used

  • Power performance testing and audits.
  • Comparing turbine designs.

Common mistakes

  • Using nacelle-anemometer speed without the transfer function.
  • Forgetting density normalisation.

Assumptions and limits

  • Steady 10-minute averages.

References

  • Power coefficient from measured performance

Questions and answers

Why does C_P fall at high wind speeds?

Above rated the pitch control sheds power to keep output constant while the wind power keeps rising with the cube of speed.

Can measured C_P exceed Betz?

No; if it seems to, the wind speed is under-measured, for example by a nacelle anemometer in the rotor wake.

What do the defaults represent?

An illustrative 1.65 MW at 8 m/s from a 120 m rotor at sea-level density and 94 % drive-train efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.