Worked example
Example: Illustrative 1.65 MW at 8 m/s, 120 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wind speed (hub height, density-normalised) | 8.0000 m/s |
| Measured electrical power | 1,650.0 kW |
| Rotor diameter | 120.00 m |
| Air density | 1.2250 kg/m³ |
| Drive-train and generator efficiency | 94.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power in the wind | 3,546.7 kW |
| Electrical power coefficient | 0.46522 |
| Rotor power coefficient | 0.49491 |
| Fraction of the Betz limit | 83.516 % |
Open this example in the calculator and change any input.
Formula
\(C_{P,e} = \frac{P}{\frac{1}{2}\rho AV^3}, \quad C_{P,r} = \frac{C_{P,e}}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Wind speed (hub height, density-normalised) | m/s |
| \(P\) | Measured electrical power | W |
| \(D\) | Rotor diameter | m |
| \(\rho\) | Air density | kg/m³ |
| \(\eta\) | Drive-train and generator efficiency | - |
| \(P_w\) | Power in the wind | W |
| \(C_{P,e}\) | Electrical power coefficient | - |
| \(C_{P,r}\) | Rotor power coefficient | - |
| \(C_{P,r}/C_{Betz}\) | Fraction of the Betz limit | - |
Method and standards
Power coefficient from data.
Where it is used
- Power performance testing and audits.
- Comparing turbine designs.
Common mistakes
- Using nacelle-anemometer speed without the transfer function.
- Forgetting density normalisation.
Assumptions and limits
- Steady 10-minute averages.
References
- Power coefficient from measured performance
Questions and answers
Why does C_P fall at high wind speeds?
Above rated the pitch control sheds power to keep output constant while the wind power keeps rising with the cube of speed.
Can measured C_P exceed Betz?
No; if it seems to, the wind speed is under-measured, for example by a nacelle anemometer in the rotor wake.
What do the defaults represent?
An illustrative 1.65 MW at 8 m/s from a 120 m rotor at sea-level density and 94 % drive-train efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 5