FireCADCalc

Measure-Correlate-Predict Long-Term Wind Speed

Long-term mean wind speed at a site from a short measurement correlated with a long-term reference station, by linear regression and by the ratio method.

Thermal power plant

Inputs

Examples: Illustrative site 6.9, reference 6.0, long term 5.6Windy year correctedCalm year corrected upwards

Accepted: 0.1 to 5
Accepted: -10 to 10 m/s
Accepted: 0.5 to 30 m/s
Accepted: 0.5 to 30 m/s
Accepted: 0.5 to 30 m/s

Results

MCP: fit site = a × reference + b over the concurrent period, then apply it to the reference station's long-term mean. Needs at least a year of concurrent data, a good correlation (r² above about 0.8) and a consistent reference record. The cube gives only a rough energy change.

Long-term site mean (regression)7.7400m/s
Long-term site mean (ratio method)7.6615m/s
Adjustment to the measured mean (regression)-6.7470%
Approximate change in energy-18.906%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative site 6.9, reference 6.0, long term 5.6. The inputs, in the units selected above:

InputValue
Regression slope (site on reference)1.0500 -
Regression intercept0.60000 m/s
Long-term mean at the reference station5.6000 m/s
Reference mean during the concurrent period6.0000 m/s
Site mean during the concurrent period6.9000 m/s

Applying the formula below gives:

ResultValue
Long-term site mean (regression)6.4800 m/s
Long-term site mean (ratio method)6.4400 m/s
Adjustment to the measured mean (regression)-6.0870 %
Approximate change in energy-17.172 %

Open this example in the calculator and change any input.

Formula

\(\bar y_{LT} = a\bar x_{LT} + b, \quad \bar y_{LT,ratio} = \bar y_c\frac{\bar x_{LT}}{\bar x_c}\)

Variables

Symbol Meaning SI unit
\(a\) Regression slope (site on reference) -
\(b\) Regression intercept m/s
\(\bar x_{LT}\) Long-term mean at the reference station m/s
\(\bar x_c\) Reference mean during the concurrent period m/s
\(\bar y_c\) Site mean during the concurrent period m/s
\(\bar y_{LT}\) Long-term site mean (regression) m/s
\(\bar y_{LT}/\bar y_c - 1\) Adjustment to the measured mean (regression) -
\((\bar y_{LT}/\bar y_c)^3 - 1\) Approximate change in energy -

Method and standards

Measure-correlate-predict.

Where it is used

  • Wind resource assessment and financing.
  • Checking a short met-mast record.

Common mistakes

  • Correlating with a station that changed instruments.
  • Using a low-correlation reference.

Assumptions and limits

  • Linear relation stable over time.

References

  • Measure-correlate-predict by linear regression

Questions and answers

Why correct a one-year measurement?

Annual mean wind varies by about ±6–10 % from year to year; a single year can mislead energy estimates by 15–25 %.

What makes a good reference station?

A long, consistent record nearby with the same weather systems, no changes of mast or surroundings, and a high correlation with the site.

What do the defaults represent?

An illustrative site measuring 6.9 m/s while the reference measured 6.0 m/s, whose long-term mean is 5.6 m/s, with a fit of 1.05x + 0.6.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.