FireCADCalc

Actuator Disc: Induction, Power and Thrust Coefficients

One-dimensional momentum theory of a wind turbine rotor: axial induction, power and thrust coefficients, disc and wake speeds, power, thrust and tower base moment.

Thermal power plant

Inputs

Examples: Illustrative 120 m rotor, a = 0.30, 9 m/sBetz optimum a = 1/3, 80 m, 11 m/sFrom C_T 0.5: 150 m rotor, 14 m/s

Accepted: 0 to 0.5
Accepted: 0 to 1
Accepted: 0.5 to 300 m
Accepted: 0 to 50 m/s
Accepted: 0.5 to 1.5 kg/m³
Accepted: 1 to 300 m

Results

Ideal actuator disc (no rotation, drag or tip losses): C_P,max = 16/27 at a = 1/3. Real rotors reach C_P of about 0.45–0.50.

Axial induction factor0.14645
Power coefficient 4a(1 − a)²0.42678
Thrust coefficient 4a(1 − a)0.50000
Speed at the disc11.950m/s
Far-wake speed9.8995m/s
Power extracted12.417MW
Rotor thrust1,039.1kN
Tower base overturning moment from thrust124,690kN·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 m rotor, a = 0.30, 9 m/s. The inputs, in the units selected above:

InputValue
GivenAxial induction factor a
Axial induction factor (Betz optimum 1/3)0.30000 -
Thrust coefficient0 -
Rotor diameter120.00 m
Free-stream wind speed9.0000 m/s
Air density1.2250 kg/m³
Hub height (for tower base moment)100.00 m

Applying the formula below gives:

ResultValue
Axial induction factor0.30000
Power coefficient 4a(1 − a)²0.58800
Thrust coefficient 4a(1 − a)0.84000
Speed at the disc6.3000 m/s
Far-wake speed3.6000 m/s
Power extracted2.9694 MW
Rotor thrust471.33 kN
Tower base overturning moment from thrust47,133 kN·m

Open this example in the calculator and change any input.

Formula

\(C_P = 4a(1 - a)^2, \quad C_T = 4a(1 - a), \quad a = \frac{1 - \sqrt{1 - C_T}}{2}, \quad T = \frac{1}{2}\rho AU^2C_T\)

Variables

Symbol Meaning SI unit
\(\text{given}\) Given -
\(a\) Axial induction factor (Betz optimum 1/3) -
\(C_T\) Thrust coefficient -
\(D\) Rotor diameter m
\(U\) Free-stream wind speed m/s
\(\rho\) Air density kg/m³
\(H\) Hub height (for tower base moment) m
\(C_P\) Power coefficient 4a(1 − a)² -
\(U_d\) Speed at the disc m/s
\(U_w\) Far-wake speed m/s
\(P\) Power extracted W
\(T\) Rotor thrust N
\(M\) Tower base overturning moment from thrust N·m

Method and standards

Actuator disc momentum theory.

Where it is used

  • Rotor design teaching and load estimates.
  • Wake models that need C_T.

Common mistakes

  • Using momentum theory above a = 0.5 (it predicts a reversed wake).
  • Taking the thrust moment as the whole tower base moment (wind on the tower adds more).

Assumptions and limits

  • Steady, uniform, inviscid flow through an ideal disc.

References

  • One-dimensional momentum (actuator disc) theory

Questions and answers

Why is the Betz limit 16/27?

Slowing the wind more extracts more energy from each kilogram but lets less air through the rotor; the best balance is a = 1/3, giving C_P = 16/27 (59.3 %).

How large is rotor thrust?

At the Betz optimum C_T = 8/9; a 120 m rotor at 9 m/s carries about 500 kN, the main load on tower and foundation.

What do the defaults represent?

An illustrative 120 m rotor at a = 0.30 in a 9 m/s wind at sea-level density, 100 m hub height.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.