Worked example
Example: Same module at standard test conditions (25 C, 1000 W/m2). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Modified ideality factor at reference (n k T N_s/q) | 0.93520 V |
| Light current at reference | 4.5490 A |
| Diode reverse saturation current at reference | 4.7820e-10 A |
| Series resistance | 0.56700 Ω |
| Shunt resistance at reference | 52.400 Ω |
| Short-circuit current temperature coefficient, A/K | 2.6000e-04 - |
| Open-circuit voltage temperature coefficient | -85.000 mV/K |
| Cell temperature | 25.000 °C |
| Reference cell temperature | 25.000 °C |
| Absorbed radiation ratio | 1.0000 - |
| Module area | 0.63300 m² |
| Incident radiation on the module | 1,000.0 W/m² |
| Cell material | Silicon (E_g 1.12 eV) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Modified ideality factor | 0.93520 V |
| Light current | 4.5490 A |
| Reverse saturation current | 4.7820e-10 A |
| Shunt resistance | 52.400 Ω |
| Short-circuit current | 4.5003 A |
| Open-circuit voltage | 21.399 V |
| Current at maximum power | 3.9502 A |
| Voltage at maximum power | 16.501 V |
| Maximum power | 65.180 W |
| Module efficiency at maximum power | 10.297 % |
| Maximum power at reference conditions (1000 W/m², T_c,ref) | 65.180 W |
| Efficiency at reference conditions | 10.297 % |
| Fill factor | 67.683 % |
| Efficiency temperature coefficient estimate η_ref μ_V,oc/V_mp,ref, 1/K | -5.3043e-04 |
Open this example in the calculator and change any input.
Formula
\(I = I_L - I_o\left[\exp\left(\frac{V + IR_s}{a}\right) - 1\right] - \frac{V + IR_s}{R_{sh}}\)
\(\frac{a}{a_{ref}} = \frac{T_c}{T_{c,ref}}, \quad I_L = \frac{S}{S_{ref}}\left[I_{L,ref} + \mu_{I,sc}(T_c - T_{c,ref})\right], \quad \frac{I_o}{I_{o,ref}} = \left(\frac{T_c}{T_{c,ref}}\right)^3\exp\left[\frac{E_{g,ref}}{kT_{c,ref}} - \frac{E_g}{kT_c}\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(a_{ref}\) | Modified ideality factor at reference (n k T N_s/q) | V |
| \(I_{L,ref}\) | Light current at reference | A |
| \(I_{o,ref}\) | Diode reverse saturation current at reference | A |
| \(R_s\) | Series resistance | Ω |
| \(R_{sh,ref}\) | Shunt resistance at reference | Ω |
| \(\mu_{I,sc}\) | Short-circuit current temperature coefficient, A/K | - |
| \(\mu_{V,oc}\) | Open-circuit voltage temperature coefficient | V/K |
| \(T_c\) | Cell temperature | K |
| \(T_{c,ref}\) | Reference cell temperature | K |
| \(S/S_{ref}\) | Absorbed radiation ratio | - |
| \(A_c\) | Module area | m² |
| \(G_T\) | Incident radiation on the module | W/m² |
| \(E_g\) | Cell material | - |
| \(a\) | Modified ideality factor | V |
| \(I_L\) | Light current | A |
| \(I_o\) | Reverse saturation current | A |
| \(R_{sh}\) | Shunt resistance | Ω |
| \(I_{sc}\) | Short-circuit current | A |
| \(V_{oc}\) | Open-circuit voltage | V |
| \(I_{mp}\) | Current at maximum power | A |
| \(V_{mp}\) | Voltage at maximum power | V |
| \(P_{mp}\) | Maximum power | W |
| \(\eta_{mp}\) | Module efficiency at maximum power | - |
| \(P_{mp,ref}\) | Maximum power at reference conditions (1000 W/m², T_c,ref) | W |
| \(\eta_{mp,ref}\) | Efficiency at reference conditions | - |
| \(FF\) | Fill factor | - |
| \(\mu_{\eta,mp}\) | Efficiency temperature coefficient estimate η_ref μ_V,oc/V_mp,ref, 1/K | - |
Method and standards
Single-diode equivalent circuit with temperature and irradiance scaling of its five parameters.
Where it is used
- Predicting module output at real cell temperatures and irradiance.
- Checking string voltages in hot and cold conditions.
- Energy yield models.
Common mistakes
- Scaling I_o linearly with temperature: it rises by orders of magnitude.
- Using incident instead of absorbed radiation ratio for S/S_ref.
Assumptions and limits
- Crystalline silicon or GaAs cells; R_s constant, R_sh ∝ 1/S.
Questions and answers
Where do the five reference parameters come from?
They are fitted to the datasheet values I_sc, V_oc, I_mp, V_mp and the V_oc temperature coefficient by solving the model's equations simultaneously.1 gives a = 0.9352 V, I_L 4.549 A, I_o 4.782 × 10⁻¹⁰ A, R_s 0.567 Ω and R_sh 52.4 Ω for a 36-cell module.
Why does power fall with temperature?
I_o rises steeply with temperature, so V_oc and V_mp fall (about −0.085 V/K here), while I_sc rises only slightly.
What do the defaults represent?
An illustrative case: Same module at standard test conditions (25 C, 1000 W/m2). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 23.2, eqs. 23.2.1 to 23.2.18 and Examples 23.2.1 and 23.2.2 (De Soto, Klein and Beckman 2006)