FireCADCalc

PV Module Single-Diode Model: Operating I–V Point and Maximum Power

Five-parameter single-diode PV model: parameters at operating cell temperature and irradiance, short-circuit current, open-circuit voltage and maximum power point.

Inputs

Examples: Same module at standard test conditions (25 C, 1000 W/m2)Cold bright day: 5 C cell temperature, S/Sref 1.05

Accepted: 0.01 to 20 V
Accepted: 0.01 to 100 A
Accepted: 1E-16 to 0.001 A
Accepted: 0 to 50 Ω
Accepted: 0.1 to 1,000,000 Ω
Accepted: -0.1 to 0.1
Accepted: -5,000 to 0 mV/K
Accepted: -73.15 to 126.85 °C
Accepted: -73.15 to 126.85 °C
Accepted: 0.001 to 2
Accepted: 0.001 to 100 m²
Accepted: 1 to 1,500 W/m²

Results

De Soto, Klein and five-parameter model: a ∝ T_c, I_L ∝ S/S_ref with μ_I,sc, I_o from the band gap, R_sh ∝ S_ref/S, R_s constant. The reference parameters come from fitting datasheet I_sc, V_oc, I_mp, V_mp and μ_V,oc.

Modified ideality factor0.87247V
Light current4.7710A
Reverse saturation current1.3159e-11A
Shunt resistance49.905Ω
Short-circuit current4.7174A
Open-circuit voltage23.133V
Current at maximum power4.1485A
Voltage at maximum power18.152V
Maximum power75.302W
Module efficiency at maximum power11.330%
Maximum power at reference conditions (1000 W/m², T_c,ref)65.180W
Efficiency at reference conditions10.297%
Fill factor69.004%
Efficiency temperature coefficient estimate η_ref μ_V,oc/V_mp,ref, 1/K-5.3043e-04

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same module at standard test conditions (25 C, 1000 W/m2). The inputs, in the units selected above:

InputValue
Modified ideality factor at reference (n k T N_s/q)0.93520 V
Light current at reference4.5490 A
Diode reverse saturation current at reference4.7820e-10 A
Series resistance0.56700 Ω
Shunt resistance at reference52.400 Ω
Short-circuit current temperature coefficient, A/K2.6000e-04 -
Open-circuit voltage temperature coefficient-85.000 mV/K
Cell temperature25.000 °C
Reference cell temperature25.000 °C
Absorbed radiation ratio1.0000 -
Module area0.63300 m²
Incident radiation on the module1,000.0 W/m²
Cell materialSilicon (E_g 1.12 eV)

Applying the formula below gives:

ResultValue
Modified ideality factor0.93520 V
Light current4.5490 A
Reverse saturation current4.7820e-10 A
Shunt resistance52.400 Ω
Short-circuit current4.5003 A
Open-circuit voltage21.399 V
Current at maximum power3.9502 A
Voltage at maximum power16.501 V
Maximum power65.180 W
Module efficiency at maximum power10.297 %
Maximum power at reference conditions (1000 W/m², T_c,ref)65.180 W
Efficiency at reference conditions10.297 %
Fill factor67.683 %
Efficiency temperature coefficient estimate η_ref μ_V,oc/V_mp,ref, 1/K-5.3043e-04

Open this example in the calculator and change any input.

Formula

\(I = I_L - I_o\left[\exp\left(\frac{V + IR_s}{a}\right) - 1\right] - \frac{V + IR_s}{R_{sh}}\)

\(\frac{a}{a_{ref}} = \frac{T_c}{T_{c,ref}}, \quad I_L = \frac{S}{S_{ref}}\left[I_{L,ref} + \mu_{I,sc}(T_c - T_{c,ref})\right], \quad \frac{I_o}{I_{o,ref}} = \left(\frac{T_c}{T_{c,ref}}\right)^3\exp\left[\frac{E_{g,ref}}{kT_{c,ref}} - \frac{E_g}{kT_c}\right]\)

Variables

Symbol Meaning SI unit
\(a_{ref}\) Modified ideality factor at reference (n k T N_s/q) V
\(I_{L,ref}\) Light current at reference A
\(I_{o,ref}\) Diode reverse saturation current at reference A
\(R_s\) Series resistance Ω
\(R_{sh,ref}\) Shunt resistance at reference Ω
\(\mu_{I,sc}\) Short-circuit current temperature coefficient, A/K -
\(\mu_{V,oc}\) Open-circuit voltage temperature coefficient V/K
\(T_c\) Cell temperature K
\(T_{c,ref}\) Reference cell temperature K
\(S/S_{ref}\) Absorbed radiation ratio -
\(A_c\) Module area m²
\(G_T\) Incident radiation on the module W/m²
\(E_g\) Cell material -
\(a\) Modified ideality factor V
\(I_L\) Light current A
\(I_o\) Reverse saturation current A
\(R_{sh}\) Shunt resistance Ω
\(I_{sc}\) Short-circuit current A
\(V_{oc}\) Open-circuit voltage V
\(I_{mp}\) Current at maximum power A
\(V_{mp}\) Voltage at maximum power V
\(P_{mp}\) Maximum power W
\(\eta_{mp}\) Module efficiency at maximum power -
\(P_{mp,ref}\) Maximum power at reference conditions (1000 W/m², T_c,ref) W
\(\eta_{mp,ref}\) Efficiency at reference conditions -
\(FF\) Fill factor -
\(\mu_{\eta,mp}\) Efficiency temperature coefficient estimate η_ref μ_V,oc/V_mp,ref, 1/K -

Method and standards

Single-diode equivalent circuit with temperature and irradiance scaling of its five parameters.

Where it is used

  • Predicting module output at real cell temperatures and irradiance.
  • Checking string voltages in hot and cold conditions.
  • Energy yield models.

Common mistakes

  • Scaling I_o linearly with temperature: it rises by orders of magnitude.
  • Using incident instead of absorbed radiation ratio for S/S_ref.

Assumptions and limits

  • Crystalline silicon or GaAs cells; R_s constant, R_sh ∝ 1/S.

Questions and answers

Where do the five reference parameters come from?

They are fitted to the datasheet values I_sc, V_oc, I_mp, V_mp and the V_oc temperature coefficient by solving the model's equations simultaneously.1 gives a = 0.9352 V, I_L 4.549 A, I_o 4.782 × 10⁻¹⁰ A, R_s 0.567 Ω and R_sh 52.4 Ω for a 36-cell module.

Why does power fall with temperature?

I_o rises steeply with temperature, so V_oc and V_mp fall (about −0.085 V/K here), while I_sc rises only slightly.

What do the defaults represent?

An illustrative case: Same module at standard test conditions (25 C, 1000 W/m2). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 23.2, eqs. 23.2.1 to 23.2.18 and Examples 23.2.1 and 23.2.2 (De Soto, Klein and Beckman 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.