Worked example
Example: Illustrative 20 modules, one shaded substring. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Modules in the string | 20.000 - |
| Bypass diodes (substrings) per module | 3.0000 - |
| Substrings containing a shaded cell | 1.0000 - |
| Shaded fraction of the worst cell | 50.000 % |
| Module maximum-power voltage | 41.500 V |
| Module maximum-power current | 9.6000 A |
| Bypass diode forward voltage | 0.40000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Unshaded string power | 7.9680 kW |
| Power with bypassed substrings | 7.8314 kW |
| Loss with bypass diodes | 1.7149 % |
| Power if the string current follows the shaded cell | 3.9840 kW |
| Loss without bypass | 50.000 % |
Open this example in the calculator and change any input.
Formula
\(P_{bypass} = I_{mp}\left[NV_{mp} - k\left(\frac{V_{mp}}{n_d} + V_d\right)\right], \quad P_{limited} = (1 - s)NV_{mp}I_{mp}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Modules in the string | - |
| \(n_d\) | Bypass diodes (substrings) per module | - |
| \(k\) | Substrings containing a shaded cell | - |
| \(s\) | Shaded fraction of the worst cell | - |
| \(V_{mp}\) | Module maximum-power voltage | V |
| \(I_{mp}\) | Module maximum-power current | A |
| \(V_d\) | Bypass diode forward voltage | V |
| \(P_0\) | Unshaded string power | W |
| \(P_{bypass}\) | Power with bypassed substrings | W |
| \(1 - P_b/P_0\) | Loss with bypass diodes | - |
| \(P_{limited}\) | Power if the string current follows the shaded cell | W |
| \(1 - P_n/P_0\) | Loss without bypass | - |
Method and standards
String shading estimate.
Where it is used
- Rooftop design near chimneys and vents.
- Diagnosing low string output.
Common mistakes
- Assuming shading loss is proportional to shaded area.
- Ignoring diode heating in long shade.
Assumptions and limits
- Identical modules; simplified I-V behaviour.
References
- Series-string shading with bypass diodes
Questions and answers
Why can one shaded cell cut a whole string?
Cells in series carry the same current; without bypass diodes the shaded cell limits the current of every module in the string.
What do bypass diodes cost in energy?
A bypassed substring loses its voltage share (a third of a module with three diodes) plus about 0.4 V, far less than the unbypassed loss.
What do the defaults represent?
An illustrative string of 20 modules (three diodes each, 41.5 V, 9.6 A) with one substring holding a half-shaded cell.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 8