PV Module Efficiency, Fill Factor and Area per kWp

Fill factor and efficiency of a PV module from its data-sheet voltages, currents, power and area, with power per square metre and area per kWp.

Thermal power plant

Inputs

Examples: Illustrative 400 W module of 2.0 m2Thin-film moduleLarge 550 W module

Accepted: 0.5 to 200 V
Accepted: 0.01 to 30 A
Accepted: 0.4 to 200 V
Accepted: 0.01 to 30 A
Accepted: 0.01 to 5 m²

Results

FF = V_mpI_mp/(V_ocI_sc); efficiency at standard test conditions (1,000 W/m², 25 °C). Crystalline modules have fill factors of about 0.75–0.82; low fill factors indicate high series resistance or shunts.

Maximum power V_mp I_mp0.55009kW
Fill factor79.218%
Efficiency at 1,000 W/m²21.321%
Power per m²213.21W/m²
Area per kWp4.6902m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 400 W module of 2.0 m2. The inputs, in the units selected above:

InputValue
Open-circuit voltage49.500 V
Short-circuit current10.200 A
Maximum-power voltage41.500 V
Maximum-power current9.6400 A
Module area2.0000 m²

Applying the formula below gives:

ResultValue
Maximum power V_mp I_mp0.40006 kW
Fill factor79.235 %
Efficiency at 1,000 W/m²20.003 %
Power per m²200.03 W/m²
Area per kWp4.9993 m²

Open this example in the calculator and change any input.

Formula

\(FF = \frac{V_{mp}I_{mp}}{V_{oc}I_{sc}}, \quad \eta = \frac{V_{mp}I_{mp}}{1000A}\)

Variables

Symbol Meaning SI unit
\(V_{oc}\) Open-circuit voltage V
\(I_{sc}\) Short-circuit current A
\(V_{mp}\) Maximum-power voltage V
\(I_{mp}\) Maximum-power current A
\(A\) Module area m²
\(P_{mp}\) Maximum power V_mp I_mp W
\(FF\) Fill factor -
\(\eta\) Efficiency at 1,000 W/m² -
\(P/A\) Power per m² W/m²
\(A/kWp\) Area per kWp m²

Method and standards

Module figures of merit.

Where it is used

  • Comparing module data sheets.
  • Area planning.

Common mistakes

  • Using gross area including frame inconsistently.
  • Comparing efficiencies at different test conditions.

Assumptions and limits

  • Standard test conditions.

References

  • PV module figures of merit

Questions and answers

What does the fill factor show?

How square the I-V curve is; resistive losses and shunts round off the knee and lower it.

How much area does 1 kWp need?

About 5 m² with 20 % modules, plus spacing between rows on flat roofs or ground.

What do the defaults represent?

An illustrative 400 W module (49.5 V, 10.2 A, 41.5 V, 9.64 A) of 2.0 m².

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.