FireCADCalc

PV Lifetime Energy with Annual Degradation

Output in the final year, total and average lifetime energy and discounted energy of a PV plant whose output falls by a fixed rate each year after first-year losses.

Thermal power plant

Inputs

Examples: Illustrative 1600 MWh, 2 % LID, 0.5 %/a, 25 a, 7 %Thin film 0.8 %/a, 30 a, 5 %Rooftop 12 MWh, 1 %/a, 20 a, 10 %

Accepted: 0.001 to 2,777,800 MWh
Accepted: 0 to 10 %
Accepted: 0 to 5 %
Accepted: 1 to 60
Accepted: 0 to 30 %

Results

Year k output E₁(1 − l₁)(1 − d)^(k−1). Warranties typically promise 80–87 % of nameplate after 25–30 years; measured rates for crystalline silicon are about 0.5 % per year.

Energy in the final year1,390.3MWh
Final-year output relative to year 1 before losses86.892%
Lifetime energy36,936MWh
Average annual energy1,477.4MWh
Discounted lifetime energy17,508MWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1600 MWh, 2 % LID, 0.5 %/a, 25 a, 7 %. The inputs, in the units selected above:

InputValue
Energy in the first year (before first-year degradation)1,600.0 MWh
First-year (light-induced) degradation2.0000 %
Annual degradation rate after year 10.50000 %
Plant life (years)25.000 -
Discount rate (for discounted energy)7.0000 %

Applying the formula below gives:

ResultValue
Energy in the final year1,390.3 MWh
Final-year output relative to year 1 before losses86.892 %
Lifetime energy36,936 MWh
Average annual energy1,477.4 MWh
Discounted lifetime energy17,508 MWh

Open this example in the calculator and change any input.

Formula

\(E_k = E_1(1 - l_1)(1 - d)^{k-1}, \quad \sum_{k=1}^{N}E_k, \quad \sum_{k=1}^{N}\frac{E_k}{(1 + r)^k}\)

Variables

Symbol Meaning SI unit
\(E_1\) Energy in the first year (before first-year degradation) J
\(l_1\) First-year (light-induced) degradation -
\(d\) Annual degradation rate after year 1 -
\(N\) Plant life (years) -
\(r\) Discount rate (for discounted energy) -
\(E_N\) Energy in the final year J
\(E_N/E_1\) Final-year output relative to year 1 before losses -
\(\sum E\) Lifetime energy J
\(\bar E\) Average annual energy J
\(\sum E/(1 + r)^n\) Discounted lifetime energy J

Method and standards

Degradation and discounting.

Where it is used

  • Financial models and warranty checks.
  • Repowering decisions.

Common mistakes

  • Applying degradation from year 0.
  • Mixing discounted and undiscounted energy in LCOE.

Assumptions and limits

  • Constant degradation rate; no repowering.

References

  • Geometric degradation of PV output

Questions and answers

How much does a panel degrade?

Typically 1–3 % in the first months (light-induced) and about 0.5 % per year after that; after 25 years output is about 86 % of the first year.

Why discount energy?

Levelised cost divides discounted costs by discounted energy; later kilowatt-hours count for less in present-value terms.

What do the defaults represent?

An illustrative 1 MWp plant making 1,600 MWh in year one, 2 % first-year loss, 0.5 % per year, 25 years and a 7 % discount rate.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.