Thermoelectric Generator Power and Efficiency

Current, power, heat input and efficiency of a thermoelectric generator from couple Seebeck coefficient, resistance, thermal conductance and temperatures.

Thermal power plant

Inputs

Examples: Illustrative 127-couple Bi2Te3, 250/50 C, best efficiencyMatched load m = 1Low gradient 80/30 C

Accepted: -23.15 to 1,226.8 °C
Accepted: -73.15 to 926.85 °C
Accepted: 10 to 2,000 µV/K
Accepted: 1E-5 to 10 Ω
Accepted: 1E-8 to 0.001 kW/K
Accepted: 1 to 10,000
Accepted: 0 to 20

Results

Couple model with constant properties: I = SΔT/[R(1 + m)], P = nI²mR, Q_h = n(KΔT + SIT_h − ½I²R). Best efficiency at m = √(1 + ZT̄); best power at m = 1. Bismuth telluride reaches ZT about 1, giving roughly 5–10 % for a 200 K difference.

Figure of merit at mean temperature1.0938
Load ratio used1.4470
Current2.0433A
Load voltage1.5020V
Electrical power0.003069kW
Heat drawn from the hot side0.11180kW
Efficiency2.7452%
Carnot efficiency14.158%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 127-couple Bi2Te3, 250/50 C, best efficiency. The inputs, in the units selected above:

InputValue
Hot-side temperature250.00 °C
Cold-side temperature50.000 °C
Seebeck coefficient per couple (V/K)400.00 µV/K
Electrical resistance per couple0.004000 Ω
Thermal conductance per couple1.2000e-05 kW/K
Couples127.00 -
Load-to-internal resistance ratio (0 for optimum √(1 + ZT̄))0 -

Applying the formula below gives:

ResultValue
Figure of merit at mean temperature1.4105
Load ratio used1.5526
Current7.8352 A
Load voltage6.1797 V
Electrical power0.048419 kW
Heat drawn from the hot side0.49744 kW
Efficiency9.7338 %
Carnot efficiency38.230 %

Open this example in the calculator and change any input.

Formula

\(I = \frac{S\Delta T}{R(1 + m)}, \quad P = nI^2mR, \quad \dot Q_h = n\left(K\Delta T + SIT_h - \frac{1}{2}I^2R\right), \quad Z = \frac{S^2}{RK}\)

Variables

Symbol Meaning SI unit
\(T_h\) Hot-side temperature K
\(T_c\) Cold-side temperature K
\(S\) Seebeck coefficient per couple (V/K) V/K
\(R\) Electrical resistance per couple Ω
\(K\) Thermal conductance per couple W/K
\(n\) Couples -
\(m\) Load-to-internal resistance ratio (0 for optimum √(1 + ZT̄)) -
\(Z\bar T\) Figure of merit at mean temperature -
\(I\) Current A
\(V\) Load voltage V
\(P\) Electrical power W
\(\dot Q_h\) Heat drawn from the hot side W
\(\eta\) Efficiency -
\(\eta_C\) Carnot efficiency -

Method and standards

Thermoelectric generation.

Where it is used

  • Waste-heat and remote power design.
  • Module selection.

Common mistakes

  • Using module data at a different temperature.
  • Ignoring contact and heat-sink resistances.

Assumptions and limits

  • Constant properties; no contact resistance.

References

  • Thermoelectric couple model

Questions and answers

Why are thermoelectric generators inefficient?

Heat leaks through the same legs that make electricity; only materials with high ZT (good Seebeck, low resistance, low conductance) do well, and ZT ≈ 1 limits efficiency to a fraction of Carnot.

Where are they used?

Space probes (radioisotope heat), remote gas pipelines, stove-powered gadgets and engine exhaust heat recovery.

What do the defaults represent?

An illustrative 127-couple bismuth telluride module (400 µV/K, 4 mΩ, 0.012 W/K per couple) between 250 °C and 50 °C at the best-efficiency load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.