FireCADCalc

Thermal (Johnson–Nyquist) Noise Power, Voltage and SNR

Thermal noise power and RMS noise voltage of a resistor or receiver over a bandwidth, the noise floor with the noise figure, and the signal-to-noise ratio.

Inputs

Examples: Illustrative: 125 kHz at 290 K, NF 6 dB, -110 dBm signalWi-Fi 20 MHz channel, NF 5 dB, -70 dBmResistor noise: 1 Mohm at 300 K over 20 kHz audio

Accepted: 1 to 2,000 K
Accepted: 1E-6 to 100,000,000 kHz
Accepted: 0.001 to 1E+12 Ω
Accepted: 0 to 30
Accepted: -200 to 50

Results

Johnson–Nyquist noise: available power kTB (−174 dBm/Hz at 290 K), open-circuit voltage √(4kTRB). The receiver adds its noise figure to the floor.

Thermal noise power (dBm)-100.96
Thermal noise power8.0078e-14W
Open-circuit RMS noise voltage √(4kTRB)4.0019e-06V
Noise floor kTB + NF (dBm)-95.965
Signal-to-noise ratio (dB)25.965

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 125 kHz at 290 K, NF 6 dB, -110 dBm signal. The inputs, in the units selected above:

InputValue
Temperature290.00 K
Bandwidth125.00 kHz
Resistance (for the noise voltage)50.000 Ω
Receiver noise figure (dB)6.0000 -
Signal power at the input (dBm)-110.00 -

Applying the formula below gives:

ResultValue
Thermal noise power (dBm)-123.01
Thermal noise power5.0049e-16 W
Open-circuit RMS noise voltage √(4kTRB)3.1638e-07 V
Noise floor kTB + NF (dBm)-117.01
Signal-to-noise ratio (dB)7.0061

Open this example in the calculator and change any input.

Formula

\(P_n = kTB, \quad v_n = \sqrt{4kTRB}, \quad N = 10\log_{10}\frac{kTB}{1\ \text{mW}} + NF, \quad SNR = P_s - N\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(B\) Bandwidth 1/s
\(R\) Resistance (for the noise voltage) Ω
\(NF\) Receiver noise figure (dB) -
\(P_s\) Signal power at the input (dBm) -
\(kTB\) Thermal noise power (dBm) -
\(v_n\) Open-circuit RMS noise voltage √(4kTRB) V
\(N\) Noise floor kTB + NF (dBm) -
\(SNR\) Signal-to-noise ratio (dB) -

Method and standards

Thermal noise physics.

Where it is used

  • Receiver sensitivity and link budget work.
  • Low-noise sensor and instrumentation amplifier design.

Common mistakes

  • Using the noise voltage of a loaded rather than open-circuit source.
  • Forgetting the receiver noise figure.

Assumptions and limits

  • Thermal equilibrium, white noise over the band.

References

  • Johnson–Nyquist thermal noise

Questions and answers

Where does −174 dBm/Hz come from?

kT at the standard 290 K is 4.0 × 10⁻²¹ W per hertz of bandwidth, which is −174 dBm in 1 Hz.

How do I lower the noise floor?

Narrow the bandwidth, use a lower-noise front end, or cool it; halving the bandwidth gains 3 dB.

What do the defaults represent?

An illustrative LoRa-type receiver: 125 kHz bandwidth at 290 K with a 6 dB noise figure and a −110 dBm signal.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Pozar, Microwave Engineering, 4th ed. (Wiley, 2012), ch. 10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.