FireCADCalc

Rise Time and Bandwidth of a System or Oscilloscope

10–90 % rise time from bandwidth, the rise time a scope and probe will display for a signal edge, and the bandwidth needed for a given error.

Inputs

Examples: Illustrative: 3 ns edge on a 200 MHz scope, 3 % error1 ns edge on a 500 MHz scopeSlow 50 ns edge on a 20 MHz scope, k 0.4

Accepted: 0.001 to 1,000,000 MHz
Accepted: 1E-4 to 1,000,000,000 ns
Accepted: 0.3 to 0.5
Accepted: 0.5 to 50 %

Results

t_r = 0.35/BW for a single-pole (Gaussian-like) response; cascaded Gaussian stages add in quadrature. Scopes with steeper roll-off have k ≈ 0.4–0.45.

Instrument rise time k/BW20.000ns
Displayed rise time √(t_sig² + t_inst²)53.852ns
Rise-time error7.7033%
Bandwidth for the allowed error24.988MHz
Knee frequency of the edge 0.5/t_r10.000MHz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 3 ns edge on a 200 MHz scope, 3 % error. The inputs, in the units selected above:

InputValue
Instrument (scope and probe) bandwidth200.00 MHz
True rise time of the signal3.0000 ns
Rise time–bandwidth constant (0.35 single pole, up to 0.45 sharp roll-off)0.35000 -
Allowed rise-time measurement error3.0000 %

Applying the formula below gives:

ResultValue
Instrument rise time k/BW1.7500 ns
Displayed rise time √(t_sig² + t_inst²)3.4731 ns
Rise-time error15.770 %
Bandwidth for the allowed error472.76 MHz
Knee frequency of the edge 0.5/t_r166.67 MHz

Open this example in the calculator and change any input.

Formula

\(t_r = \frac{k}{BW}\ (k \approx 0.35), \quad t_{r,meas} = \sqrt{t_{r,sig}^2 + t_{r,inst}^2}, \quad f_{knee} = \frac{0.5}{t_r}\)

Variables

Symbol Meaning SI unit
\(BW\) Instrument (scope and probe) bandwidth 1/s
\(t_{r,sig}\) True rise time of the signal s
\(k\) Rise time–bandwidth constant (0.35 single pole, up to 0.45 sharp roll-off) -
\(\varepsilon\) Allowed rise-time measurement error -
\(t_{r,inst}\) Instrument rise time k/BW s
\(t_{r,meas}\) Displayed rise time √(t_sig² + t_inst²) s
\(\varepsilon_{meas}\) Rise-time error -
\(BW_{needed}\) Bandwidth for the allowed error 1/s
\(f_{knee}\) Knee frequency of the edge 0.5/t_r 1/s

Method and standards

Bandwidth–rise-time relations.

Where it is used

  • Choosing oscilloscopes and probes.
  • Signal integrity and high-speed digital design.

Common mistakes

  • Assuming the scope shows the true edge.
  • Ignoring the probe bandwidth.

Assumptions and limits

  • Gaussian-like responses adding in quadrature.

References

  • Rise time–bandwidth relation and quadrature addition

Questions and answers

How much bandwidth does my scope need?

For about 3 % rise-time error the instrument must be roughly four times faster than the signal edge; the 'five times the clock' rule is a rough version of the same idea.

Where does 0.35 come from?

For a single-pole low-pass, the 10–90 % rise time is ln 9/(2π f₋₃dB) ≈ 0.35/f₋₃dB.

What do the defaults represent?

An illustrative 3 ns edge viewed on a 200 MHz scope and probe, aiming for 3 % error.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.