FireCADCalc

Inductor Turns from the Core A_L Value and Peak Flux Density

Number of turns for a required inductance from a core's inductance factor A_L, the actual inductance with whole turns, and the peak flux density at the peak current.

Inputs

Examples: Illustrative: 47 uH, A_L 250 nH, A_e 40 mm2, 2.5 A peak, ferritePowder toroid 100 uH, A_L 75 nH, 65 mm2, 4 ASmall ungapped ferrite 1 mH, A_L 2000 nH, 20 mm2, 0.3 A (saturation warning)

Accepted: 0.001 to 10,000,000 µH
Accepted: 1 to 100,000 nH
Accepted: 0.1 to 10,000 mm²
Accepted: 0 to 1,000 A
Accepted: 0.05 to 2.5 T

Results

L = A_L N²; peak flux B = L I/(N A_e). Keep B below about 70–80 % of saturation at the hottest temperature (ferrite B_sat falls with temperature).

Turns (rounded up)37.000
Exact turns √(L/A_L)36.515
Inductance with the rounded turns102.67µH
Peak flux density L I/(N A_e)170.77mT
Fraction of saturation17.077%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 47 uH, A_L 250 nH, A_e 40 mm2, 2.5 A peak, ferrite. The inputs, in the units selected above:

InputValue
Required inductance47.000 µH
Inductance factor of the core (per turn²)250.00 nH
Effective core area40.000 mm²
Peak current2.5000 A
Saturation flux density of the core material0.35000 T

Applying the formula below gives:

ResultValue
Turns (rounded up)14.000
Exact turns √(L/A_L)13.711
Inductance with the rounded turns49.000 µH
Peak flux density L I/(N A_e)218.75 mT
Fraction of saturation62.500 %

Open this example in the calculator and change any input.

Formula

\(N = \left\lceil\sqrt{\frac{L}{A_L}}\right\rceil, \quad L = A_LN^2, \quad B_{pk} = \frac{L\,I_{pk}}{N\,A_e}\)

Variables

Symbol Meaning SI unit
\(L\) Required inductance H
\(A_L\) Inductance factor of the core (per turn²) H
\(A_e\) Effective core area m²
\(I_{pk}\) Peak current A
\(B_{sat}\) Saturation flux density of the core material T
\(N\) Turns (rounded up) -
\(N_{exact}\) Exact turns √(L/A_L) -
\(L_{actual}\) Inductance with the rounded turns H
\(B_{pk}\) Peak flux density L I/(N A_e) T
\(B_{pk}/B_{sat}\) Fraction of saturation -

Method and standards

Inductor winding from catalogue core data.

Where it is used

  • Switch-mode power supply inductors and chokes.
  • EMI filters and RF coils.

Common mistakes

  • Using A_L in µH per 100 turns as nH per turn².
  • Checking saturation at the average instead of the peak current.

Assumptions and limits

  • A_L constant (no saturation), uniform flux in the core.

References

  • Inductance factor A_L and peak flux density

Questions and answers

What is A_L?

The inductance per turn squared that the core maker quotes (often in nH/N²); it already includes the core's permeability, path length and any air gap.

Why check the flux density?

A ferrite inductor that saturates loses its inductance suddenly and the current spikes; peak current, not average, sets the flux.

What do the defaults represent?

An illustrative 47 µH inductor on a gapped ferrite core with A_L 250 nH/N², A_e 40 mm² and 2.5 A peak.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

McLyman, Transformer and Inductor Design Handbook, 4th ed. (CRC Press, 2011), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.