Worked example
Example: Illustrative: 47 uH, A_L 250 nH, A_e 40 mm2, 2.5 A peak, ferrite. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Required inductance | 47.000 µH |
| Inductance factor of the core (per turn²) | 250.00 nH |
| Effective core area | 40.000 mm² |
| Peak current | 2.5000 A |
| Saturation flux density of the core material | 0.35000 T |
Applying the formula below gives:
| Result | Value |
|---|---|
| Turns (rounded up) | 14.000 |
| Exact turns √(L/A_L) | 13.711 |
| Inductance with the rounded turns | 49.000 µH |
| Peak flux density L I/(N A_e) | 218.75 mT |
| Fraction of saturation | 62.500 % |
Open this example in the calculator and change any input.
Formula
\(N = \left\lceil\sqrt{\frac{L}{A_L}}\right\rceil, \quad L = A_LN^2, \quad B_{pk} = \frac{L\,I_{pk}}{N\,A_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Required inductance | H |
| \(A_L\) | Inductance factor of the core (per turn²) | H |
| \(A_e\) | Effective core area | m² |
| \(I_{pk}\) | Peak current | A |
| \(B_{sat}\) | Saturation flux density of the core material | T |
| \(N\) | Turns (rounded up) | - |
| \(N_{exact}\) | Exact turns √(L/A_L) | - |
| \(L_{actual}\) | Inductance with the rounded turns | H |
| \(B_{pk}\) | Peak flux density L I/(N A_e) | T |
| \(B_{pk}/B_{sat}\) | Fraction of saturation | - |
Method and standards
Inductor winding from catalogue core data.
Where it is used
- Switch-mode power supply inductors and chokes.
- EMI filters and RF coils.
Common mistakes
- Using A_L in µH per 100 turns as nH per turn².
- Checking saturation at the average instead of the peak current.
Assumptions and limits
- A_L constant (no saturation), uniform flux in the core.
References
- Inductance factor A_L and peak flux density
Questions and answers
What is A_L?
The inductance per turn squared that the core maker quotes (often in nH/N²); it already includes the core's permeability, path length and any air gap.
Why check the flux density?
A ferrite inductor that saturates loses its inductance suddenly and the current spikes; peak current, not average, sets the flux.
What do the defaults represent?
An illustrative 47 µH inductor on a gapped ferrite core with A_L 250 nH/N², A_e 40 mm² and 2.5 A peak.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
McLyman, Transformer and Inductor Design Handbook, 4th ed. (CRC Press, 2011), ch. 8