Worked example
Example: Illustrative: 20 A, 50 mV shunt, 3.3 V 12-bit ADC, 7.5 A now. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Maximum current to measure | 20.000 A |
| Shunt voltage at full scale | 50.000 mV |
| ADC full-scale input | 3.3000 V |
| ADC resolution (bits) | 12.000 - |
| Present current | 7.5000 A |
Applying the formula below gives:
| Result | Value |
|---|---|
| Shunt resistance | 2.5000 mΩ |
| Shunt power at full current | 1.0000 W |
| Amplifier gain to reach ADC full scale | 66.000 |
| Current per ADC count | 4.8828 mA |
| ADC input at the present current | 1.2375 V |
| ADC counts at the present current | 1,535.0 |
Open this example in the calculator and change any input.
Formula
\(R_{sh} = \frac{V_{sh,max}}{I_{max}}, \quad P = I_{max}^2R_{sh}, \quad G = \frac{V_{FS}}{V_{sh,max}}, \quad I_{LSB} = \frac{I_{max}}{2^n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I_{max}\) | Maximum current to measure | A |
| \(V_{sh,max}\) | Shunt voltage at full scale | V |
| \(V_{FS}\) | ADC full-scale input | V |
| \(n\) | ADC resolution (bits) | - |
| \(I\) | Present current | A |
| \(R_{sh}\) | Shunt resistance | Ω |
| \(P_{max}\) | Shunt power at full current | W |
| \(G\) | Amplifier gain to reach ADC full scale | - |
| \(I_{LSB}\) | Current per ADC count | A |
| \(V_{ADC}\) | ADC input at the present current | V |
| \(N\) | ADC counts at the present current | - |
Method and standards
Shunt measurement scaling.
Where it is used
- Battery management, motor drives and power monitors.
- DC panel meters and data loggers.
Common mistakes
- Forgetting the shunt temperature rise and its tempco.
- Measuring across the leads instead of the Kelvin terminals.
Assumptions and limits
- Ideal amplifier; linear ADC.
References
- Shunt current measurement and ADC scaling
Questions and answers
Why not use a bigger shunt voltage?
A bigger drop improves accuracy against offsets but wastes power and heats the shunt; 50–100 mV is the usual compromise.
What is a Kelvin connection?
Separate sense wires taken from the shunt's own terminals so the drop in the current-carrying leads and solder joints is not measured.
What do the defaults represent?
An illustrative 20 A full-scale measurement with a 50 mV shunt into a 3.3 V, 12-bit ADC, now reading 7.5 A.