FireCADCalc

Coaxial Cable Characteristic Impedance, Capacitance and Velocity

Characteristic impedance, capacitance and inductance per metre, velocity factor and delay of a coaxial line from its conductor diameters and dielectric constant.

Inputs

Examples: Illustrative: RG-213 size, 2.26 mm in a 7.24 mm shield, PE75 ohm foam TV cable: 1.0 mm in 4.6 mm, er 1.4Air line 3.5 mm: 1.52 mm in 3.5 mm

Accepted: 0.01 to 1,000 mm
Accepted: 0.001 to 1,000 mm
Accepted: 1 to 20

Results

Lossless coaxial line: Z₀ = (60/√ε_r) ln(D/d) Ω. The delay is shown in nanoseconds per metre.

Characteristic impedance50.009Ω
Capacitance per metre66.701pF/m
Inductance per metre0.16681µH/m
Velocity factor 1/√ε_r1.0000
Delay per metre (ns/m)3.3356

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: RG-213 size, 2.26 mm in a 7.24 mm shield, PE. The inputs, in the units selected above:

InputValue
Inner diameter of the outer conductor (shield)7.2400 mm
Diameter of the inner conductor2.2600 mm
Relative permittivity of the dielectric (PE 2.25, PTFE 2.1, foam ≈1.5)2.2500 -

Applying the formula below gives:

ResultValue
Characteristic impedance46.538 Ω
Capacitance per metre107.51 pF/m
Inductance per metre0.23285 µH/m
Velocity factor 1/√ε_r0.66667
Delay per metre (ns/m)5.0035

Open this example in the calculator and change any input.

Formula

\(Z_0 = \frac{60}{\sqrt{\varepsilon_r}}\ln\frac{D}{d}, \quad C' = \frac{2\pi\varepsilon_0\varepsilon_r}{\ln(D/d)}, \quad L' = \frac{\mu_0}{2\pi}\ln\frac{D}{d}, \quad VF = \frac{1}{\sqrt{\varepsilon_r}}\)

Variables

Symbol Meaning SI unit
\(D\) Inner diameter of the outer conductor (shield) m
\(d\) Diameter of the inner conductor m
\(\varepsilon_r\) Relative permittivity of the dielectric (PE 2.25, PTFE 2.1, foam ≈1.5) -
\(Z_0\) Characteristic impedance Ω
\(C'\) Capacitance per metre F/m
\(L'\) Inductance per metre H/m
\(VF\) Velocity factor 1/√ε_r -
\(t_d\) Delay per metre (ns/m) -

Method and standards

Coaxial line theory.

Where it is used

  • Selecting and checking RF cables and connectors.
  • Designing coaxial stubs, couplers and sensors.

Common mistakes

  • Using the outer diameter of the jacket instead of the shield.
  • Ignoring the dielectric constant of foam dielectrics.

Assumptions and limits

  • Lossless line, TEM mode, non-magnetic materials.

References

  • Coaxial transmission line parameters

Questions and answers

Why 50 Ω and 75 Ω?

75 Ω (D/d ≈ 3.6 in air) gives the lowest loss; about 30 Ω handles the most power; 50 Ω is the compromise used in most RF systems, while 75 Ω suits video and cable TV.

What is the velocity factor used for?

To cut cables to a fraction of a wavelength (stubs, phasing lines) and to locate faults by time-domain reflectometry.

What do the defaults represent?

An illustrative RG-213-size cable: a 2.26 mm inner conductor inside a 7.24 mm shield with solid polyethylene.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Pozar, Microwave Engineering, 4th ed. (Wiley, 2012), ch. 2

Related calculators