Worked example
Example: Illustrative: RG-213 size, 2.26 mm in a 7.24 mm shield, PE. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inner diameter of the outer conductor (shield) | 7.2400 mm |
| Diameter of the inner conductor | 2.2600 mm |
| Relative permittivity of the dielectric (PE 2.25, PTFE 2.1, foam ≈1.5) | 2.2500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Characteristic impedance | 46.538 Ω |
| Capacitance per metre | 107.51 pF/m |
| Inductance per metre | 0.23285 µH/m |
| Velocity factor 1/√ε_r | 0.66667 |
| Delay per metre (ns/m) | 5.0035 |
Open this example in the calculator and change any input.
Formula
\(Z_0 = \frac{60}{\sqrt{\varepsilon_r}}\ln\frac{D}{d}, \quad C' = \frac{2\pi\varepsilon_0\varepsilon_r}{\ln(D/d)}, \quad L' = \frac{\mu_0}{2\pi}\ln\frac{D}{d}, \quad VF = \frac{1}{\sqrt{\varepsilon_r}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Inner diameter of the outer conductor (shield) | m |
| \(d\) | Diameter of the inner conductor | m |
| \(\varepsilon_r\) | Relative permittivity of the dielectric (PE 2.25, PTFE 2.1, foam ≈1.5) | - |
| \(Z_0\) | Characteristic impedance | Ω |
| \(C'\) | Capacitance per metre | F/m |
| \(L'\) | Inductance per metre | H/m |
| \(VF\) | Velocity factor 1/√ε_r | - |
| \(t_d\) | Delay per metre (ns/m) | - |
Method and standards
Coaxial line theory.
Where it is used
- Selecting and checking RF cables and connectors.
- Designing coaxial stubs, couplers and sensors.
Common mistakes
- Using the outer diameter of the jacket instead of the shield.
- Ignoring the dielectric constant of foam dielectrics.
Assumptions and limits
- Lossless line, TEM mode, non-magnetic materials.
References
- Coaxial transmission line parameters
Questions and answers
Why 50 Ω and 75 Ω?
75 Ω (D/d ≈ 3.6 in air) gives the lowest loss; about 30 Ω handles the most power; 50 Ω is the compromise used in most RF systems, while 75 Ω suits video and cable TV.
What is the velocity factor used for?
To cut cables to a fraction of a wavelength (stubs, phasing lines) and to locate faults by time-domain reflectometry.
What do the defaults represent?
An illustrative RG-213-size cable: a 2.26 mm inner conductor inside a 7.24 mm shield with solid polyethylene.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Pozar, Microwave Engineering, 4th ed. (Wiley, 2012), ch. 2