Worked example
Example: Ball mill 4.12 m, 64 mm balls, 71.7 % of critical (Wills Table ex 7.2). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mill diameter inside the liners | 4.1200 m |
| Largest ball or rod diameter | 64.000 mm |
| Operating speed as a fraction of critical | 71.700 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical speed | 20.999 rpm |
| Operating speed | 15.056 rpm |
| Angle of release of the outer balls from the vertical | 59.063 ° |
| Shell peripheral speed | 3.2480 m/s |
Open this example in the calculator and change any input.
Formula
\(N_c = \frac{42.3}{\sqrt{D - d}}\ \text{rpm}, \quad \cos\alpha = \frac{(2\pi N/60)^2 (D - d)/2}{g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Mill diameter inside the liners | m |
| \(d\) | Largest ball or rod diameter | m |
| \(N/N_c\) | Operating speed as a fraction of critical | - |
| \(N_c\) | Critical speed | 1/s |
| \(N\) | Operating speed | 1/s |
| \(\alpha\) | Angle of release of the outer balls from the vertical | rad |
| \(v\) | Shell peripheral speed | m/s |
Method and standards
Balance of weight and centrifugal force on the outer ball.
Where it is used
- Setting mill speed and variable-speed drives.
- Checking liner and lifter design.
Common mistakes
- Using the shell diameter instead of inside the liners.
- Confusing rpm with fraction of critical.
Assumptions and limits
- No slip at the liner.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 7
- eqs. 7.1-7.4
- Perry's Chemical Engineers' Handbook
- 9th ed.
- sec. 21
- eq. 21-143
Questions and answers
What happens at critical speed?
The outer layer of balls is held against the shell all the way round and no longer falls, so grinding stops.
Why include the ball size?
The ball centre runs at radius (D − d)/2; for large mills the correction is small.
What do the defaults represent?
The 4.12 m ball mill of Wills's Table ex 7.2 with 64 mm balls at 71.7 % of critical.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.