Worked example
Example: Wills Example 12.2: 24,000 t/d at 35 % solids, 7 cells. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry solids feed rate | 1,000.0 t/h |
| Availability | 100.00 % |
| Laboratory flotation time | 5.0000 min |
| Scale-up factor on time (2–2.5) | 2.5000 - |
| Gas holdup (air in the pulp) | 15.000 % |
| Solids by mass in the pulp | 35.000 % |
| Ore density | 3.0000 g/cm³ |
| Number of cells in the bank | 7.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pulp volume per tonne of solids | 2.1905 m³/t |
| Plant retention time | 12.500 min |
| Pulp expansion factor | 1.1765 |
| Total effective bank volume | 536.88 m³ |
| Effective volume per cell | 76.697 m³ |
Open this example in the calculator and change any input.
Formula
\(N V_{eff} = \frac{F T E P}{60}, \quad T = t_{lab} f_s, \quad E = \frac{1}{1 - GH}, \quad P = \frac{1}{\rho_s} + \frac{100}{x} - 1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F\) | Dry solids feed rate | kg/s |
| \(a\) | Availability | - |
| \(t_{lab}\) | Laboratory flotation time | s |
| \(f_s\) | Scale-up factor on time (2–2.5) | - |
| \(GH\) | Gas holdup (air in the pulp) | - |
| \(x\) | Solids by mass in the pulp | - |
| \(\rho_s\) | Ore density | kg/m³ |
| \(N\) | Number of cells in the bank | - |
| \(P\) | Pulp volume per tonne of solids | m³/kg |
| \(T\) | Plant retention time | s |
| \(E\) | Pulp expansion factor | - |
| \(N V_{eff}\) | Total effective bank volume | m³ |
| \(V_{eff}\) | Effective volume per cell | m³ |
Method and standards
Wood's cell sizing method.
Where it is used
- Sizing rougher, scavenger and cleaner banks.
- Checking an existing bank for higher tonnage.
Common mistakes
- Ignoring availability.
- Using total cell volume as effective volume.
Assumptions and limits
- Mixed cells; scale-up factor from experience.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 12
- eq. 12.54 (Wood, 2002) and Example 12.2
Questions and answers
Why scale up the laboratory time?
Plant cells are mixed, have short-circuiting and a froth phase that drops recovery, so they need 2 to 2.5 times the laboratory time.
What is the expansion factor?
Air in the pulp takes volume; with 15 % gas holdup the cell holds 1/0.85 times the pulp volume.
What do the defaults represent?
Wills's Example 12.2: 24,000 t/d at 35 % solids, ore density 3, 5 minutes laboratory time × 2.5 (537 m³, about 77 m³ per cell in seven cells).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.