FireCADCalc

Classifier Partition Curve with Bypass and Imperfection

Corrected and actual partition to underflow at a size from d50c, sharpness m and water bypass, with actual d50, d25, d75, imperfection and stages in series.

Inputs

Examples: Wills Example 9.2 fit: d50c 125 µm, m 1.7, bypass 32 %Sharp cyclone with low bypass, 2 in seriesFine screen-like separation

Results

The corrected curve is the Plitt/Whiten form fitted by d50c and m; the actual curve adds the fines carried to the underflow with the water (bypass, Kelsall). m above 3 is rare in cyclones. Imperfection here uses the corrected curve.

Corrected partition to underflow29.875%
Actual partition to underflow40.394%
Actual cut size (S = 50 %)68.609µm
Size with 25 % corrected partition55.944µm
Size with 75 % corrected partition94.494µm
Imperfection0.25700
Recovery of size d to the combined underflow of N in series64.471%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Wills Example 9.2 fit: d50c 125 µm, m 1.7, bypass 32 %. The inputs, in the units selected above:

InputValue
Corrected cut size125.00 µm
Sharpness of separation1.7000 -
Bypass (fraction of feed water to underflow)32.000 %
Particle size of interest150.00 µm
Identical classifiers in series (each re-treating the overflow)1.0000 -

Applying the formula below gives:

ResultValue
Corrected partition to underflow61.132 %
Actual partition to underflow73.570 %
Actual cut size (S = 50 %)77.493 µm
Size with 25 % corrected partition74.517 µm
Size with 75 % corrected partition187.93 µm
Imperfection0.45364
Recovery of size d to the combined underflow of N in series73.570 %

Open this example in the calculator and change any input.

Formula

\(C(d) = 1 - \exp\left[-0.693\left(\frac{d}{d_{50c}}\right)^m\right], \quad S = R_f + (1 - R_f)C, \quad I = \frac{d_{75} - d_{25}}{2d_{50}}, \quad R_N = 1 - (1 - S)^N\)

Variables

Symbol Meaning SI unit
\(d_{50c}\) Corrected cut size m
\(m\) Sharpness of separation -
\(R_f\) Bypass (fraction of feed water to underflow) -
\(d\) Particle size of interest m
\(N\) Identical classifiers in series (each re-treating the overflow) -
\(C(d)\) Corrected partition to underflow -
\(S(d)\) Actual partition to underflow -
\(d_{50}\) Actual cut size (S = 50 %) m
\(d_{25}\) Size with 25 % corrected partition m
\(d_{75}\) Size with 75 % corrected partition m
\(I\) Imperfection -
\(R_N(d)\) Recovery of size d to the combined underflow of N in series -

Method and standards

Partition curve with bypass.

Where it is used

  • Evaluating cyclone surveys.
  • Grinding circuit simulation.

Common mistakes

  • Fitting the actual curve without removing bypass.
  • Reading d50 from the corrected curve as the actual cut.

Assumptions and limits

  • Plitt/Whiten curve shape; bypass equal to water split.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 9
  • eqs. 9.16-9.19 (Plitt, 1976; Kelsall, 1953)
  • eq. 9.28 (Svarovsky and Thew, 1984) and Example 9.2

Questions and answers

What is the bypass?

Fine particles that follow the water to the underflow without being classified; it equals roughly the water split to underflow.

Why are actual and corrected cut sizes different?

The bypass lifts the whole curve, so the actual 50 % point falls at a finer size than the corrected one.

What do the defaults represent?

Wills's Example 9.2 fit: d50c 125 µm, m 1.7 and 32 % water to underflow, read at 150 µm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.