FireCADCalc

Well Yield by the Thiem Equation (Confined and Unconfined)

Steady yield of a pumped well in a confined or unconfined aquifer from permeability, aquifer thickness, drawdown, well radius and radius of influence (Thiem).

Inputs

Examples: Unconfined, 20 m saturatedConfined, 15 m thick

Results

Sichardt's estimate (s in m, K in m/s) is a rough empirical guide; a pumping test gives the real radius.

Well yield119.51m³/h
Sichardt estimate of the radius of influence 3000 s √K402.49m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Unconfined, 20 m saturated. The inputs, in the units selected above:

InputValue
AquiferUnconfined (water table)
Hydraulic conductivity2.0000e-04 m/s
Aquifer thickness (confined) or saturated thickness (unconfined)20.000 m
Drawdown at the well4.0000 m
Well radius150.00 mm
Radius of influence300.00 m
Confined only: static head above the top of the aquifer (0 = not checked)0 m

Applying the formula below gives:

ResultValue
Well yield42.853 m³/h
Sichardt estimate of the radius of influence 3000 s √K169.71 m

Open this example in the calculator and change any input.

Formula

\(Q = \frac{2\pi K b s_w}{\ln(R/r_w)} \ \text{(confined)}, \quad Q = \frac{\pi K (H^2 - h_w^2)}{\ln(R/r_w)} \ \text{(unconfined)}\)

Variables

Symbol Meaning SI unit
\(\text{aquifer}\) Aquifer -
\(K\) Hydraulic conductivity m/s
\(b / H\) Aquifer thickness (confined) or saturated thickness (unconfined) m
\(s_w\) Drawdown at the well m
\(r_w\) Well radius m
\(R\) Radius of influence m
\(h_c\) Confined: static head above the top of the aquifer (0 = not checked) m
\(h_w\) Unconfined: water depth in the well, H − s_w m
\(Q\) Well yield m³/s
\(R_S\) Sichardt estimate of the radius of influence 3000 s √K m

Method and standards

Radial steady flow.

Where it is used

  • Plant water supply wells.
  • Dewatering.

Common mistakes

  • Unconfined formula with drawdown instead of heads.
  • Ignoring well losses.

Assumptions and limits

  • The confined equation holds only while the water level stays above the top of the aquifer. Enter the static head above the aquifer top to have the page warn when the drawdown exceeds it.

  • Steady, homogeneous, fully penetrating well.

References

  • Thiem (1906) steady radial flow; Dupuit–Forchheimer for unconfined aquifers; Sichardt radius of influence (empirical)

Questions and answers

Unconfined, K 2e-4 m/s, 20 m thick, 4 m drawdown?

About 43 m³/h with R 300 m.

Does R matter much?

Only through its logarithm, so a rough R is fine.

Steady state?

Thiem assumes pumping has gone on long enough for steady flow.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.