Worked example
Example: 5 ha site, 0.25 m3/s allowed. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Runoff coefficient | 80.000 % |
| Catchment area | 5.0000 ha |
| Time of concentration | 10.000 min |
| Allowed outflow | 0.25000 m³/s |
| Rainfall curve i = a/(t + b)^n: a (mm/h with t in min) | 3,000.0 - |
| b (minutes) | 20.000 - |
| n | 0.80000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical storm duration | 194.28 min |
| Intensity at the critical duration | 40.958 mm/h |
| Peak inflow C i A | 0.45509 m³/s |
| Storage volume needed | 3,772.7 m³ |
Open this example in the calculator and change any input.
Formula
\(V(t_d) = C\, i(t_d)\, A\, t_d - \frac{Q_o (t_d + t_c)}{2}, \quad i = \frac{a}{(t + b)^n}, \quad V = \max_{t_d} V(t_d)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Runoff coefficient | - |
| \(A\) | Catchment area | m² |
| \(t_c\) | Time of concentration | s |
| \(Q_o\) | Allowed outflow | m³/s |
| \(a\) | Rainfall curve i = a/(t + b)^n: a (mm/h with t in min) | - |
| \(b\) | b (minutes) | - |
| \(n\) | n | - |
| \(t_d\) | Critical storm duration | s |
| \(i\) | Intensity at the critical duration | m/s |
| \(Q_i\) | Peak inflow C i A | m³/s |
| \(V\) | Storage volume needed | m³ |
Method and standards
Modified rational method.
Where it is used
- Plant storm water ponds.
- Roof and yard detention tanks.
Common mistakes
- Intensity units.
- Using it for large catchments.
Assumptions and limits
- Small catchments, linear outflow rise.
- Durations from t_c to 24 h are searched; a maximum at the 24-hour limit is flagged as a lower bound.
References
- Modified rational method V = Q_i t_d − ½Q_o(t_d + t_c) (FHWA HEC-22 practice); intensity curve i = a/(t + b)^n
Questions and answers
What does the default site need?
A 5 ha site at C 0.8 limited to 0.25 m³/s needs about 3,800 m³; the critical storm lasts about 3¼ hours.
Why search over durations?
Longer storms have less intensity but more volume; the worst one sets the storage.
Large catchments?
Use a hydrograph routing method instead.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.