FireCADCalc

Gradually Varied Flow: Backwater Length in a Rectangular Channel

Normal and critical depths and the distance between two depths of a backwater or drawdown profile in a rectangular channel (GVF equation).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 10 m channel, 20 m³/s, weir raises to 3 mDrawdown towards a fall: 0.8 → 1.05 m

Results

dx/dy = (1 − Fr²)/(S₀ − S_f) integrated by Simpson's rule (the limit of the direct step method). For a mild-slope backwater (M1) from a dam or weir, y₁ is the depth at the structure and the distance is measured upstream. Rectangular section; Manning friction.

Normal depth1.0930m
Critical depth0.56596m
Distance between y₁ and y₂ (upstream +)541.42m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m channel, 20 m³/s, weir raises to 3 m. The inputs, in the units selected above:

InputValue
Discharge72,000 m³/h
Channel width10.000 m
Manning's n0.025000 -
Bed slope4.0000e-04 -
Depth at the control (start)3.0000 m
Depth at the end2.3000 m

Applying the formula below gives:

ResultValue
Normal depth1.9803 m
Critical depth0.74162 m
Distance between y₁ and y₂ (upstream +)3,172.3 m

Open this example in the calculator and change any input.

Formula

\(\frac{dx}{dy} = \frac{1 - Fr^2}{S_0 - S_f}, \quad S_f = \left(\frac{nQ}{AR^{2/3}}\right)^2, \quad Fr^2 = \frac{Q^2}{gb^2y^3}\)

Variables

Symbol Meaning SI unit
\(Q\) Discharge m³/s
\(b\) Channel width m
\(n\) Manning's n -
\(S_0\) Bed slope -
\(y_1\) Depth at the control (start) m
\(y_2\) Depth at the end m
\(y_n\) Normal depth m
\(y_c\) Critical depth m
\(\Delta x\) Distance between y₁ and y₂ (upstream +) m

Method and standards

GVF equation.

Where it is used

  • Intake weirs and cooling water channels.
  • Flood levels upstream of structures.

Common mistakes

  • Starting from the wrong control.
  • Crossing normal depth.

Assumptions and limits

  • Rectangular prismatic channel; steady flow.
  • A depth very close to normal depth makes the integral converge slowly; a result whose Simpson estimate changes by more than 1 % when the step is halved is flagged.

References

  • Gradually varied flow equation dy/dx = (S₀ − S_f)/(1 − Fr²) (Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 9–10)

Questions and answers

How far upstream does a weir raise the water?

The backwater curve approaches normal depth asymptotically; it is common to stop at 1–2 % above normal depth.

Why can't the depths cross normal or critical depth?

The GVF equation is singular there; each zone has its own profile type.

What do the defaults represent?

A 10 m wide channel carrying 20 m³/s on a mild slope with a weir raising the depth to 3 m.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.