FireCADCalc

Initial Water Injectivity of a Five-Spot Pattern (Muskat)

Base (initial) water injection rate and injectivity of a five-spot pattern full of oil, from thickness, permeability, oil relative permeability and well spacing.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 40-acre five-spot, 25 ft of 120 mD sand

Accepted: 0.32808 to 1,640.4 ft
Accepted: 0.00010132 to 101,320 mD
Accepted: 0.01 to 1
Accepted: 0.01 to 1,000 cP
Accepted: 32.808 to 32,808 ft
Accepted: 0.098425 to 3.2808 ft
Accepted: 0.00014504 to 14,504 psi
Accepted: 0.05 to 20

Results

Liquid-filled five-spot at the start of the flood (no free gas). As the flood proceeds the injectivity changes by the conductance ratio γ (Caudle and Witte), which depends on the mobility ratio and areal sweep; read it from their chart and enter it.

Base (initial) injection rate622.04bbl/d
Base injectivity0.41469bbl/(d·psi)
Injection rate at the conductance ratio entered870.86bbl/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40-acre five-spot, 25 ft of 120 mD sand. The inputs, in the units selected above:

InputValue
Net thickness25.000 ft
Absolute permeability120.00 mD
Oil relative permeability at initial water saturation0.85000 -
Oil viscosity3.0000 cP
Distance between injector and producer933.00 ft
Wellbore radius0.35400 ft
Injection pressure minus producing bottom-hole pressure1,500.0 psi
Conductance ratio at the stage of the flood (1 at start)1.4000 -

Applying the formula below gives:

ResultValue
Base (initial) injection rate622.04 bbl/d
Base injectivity0.41469 bbl/(d·psi)
Injection rate at the conductance ratio entered870.86 bbl/d

Open this example in the calculator and change any input.

Formula

\(i_{base} = \frac{\pi hkk_{ro}\Delta p}{\mu_o\left[\ln(d/r_w) - 0.619\right]}\ \ \left(= \frac{0.003541hkk_{ro}\Delta p}{\mu_o[\ln(d/r_w) - 0.619]}\ \text{field}\right), \quad i_w = \gamma\,i_{base}\)

Variables

Symbol Meaning SI unit
\(h\) Net thickness m
\(k\) Absolute permeability m²
\(k_{ro}\) Oil relative permeability at initial water saturation -
\(\mu_o\) Oil viscosity Pa·s
\(d\) Distance between injector and producer m
\(r_w\) Wellbore radius m
\(\Delta p\) Injection pressure minus producing bottom-hole pressure Pa
\(\gamma\) Conductance ratio at the stage of the flood (1 at start) -
\(i_{base}\) Base (initial) injection rate m³/s
\(I_{base}\) Base injectivity m³/(s·Pa)
\(i_w\) Injection rate at the conductance ratio entered m³/s

Method and standards

Muskat's five-spot injectivity.

Where it is used

  • Waterflood injection planning.
  • Sizing injection pumps.

Common mistakes

  • Using the pattern side instead of the injector-producer distance.
  • Ignoring free gas at the start of the flood.

Assumptions and limits

  • Liquid-filled five-spot; steady state.

Questions and answers

What is the conductance ratio?

The injectivity at a stage of the flood divided by the initial injectivity; below 1 when water is less mobile than oil (M < 1), above 1 when it is more mobile.

Why ln(d/r_w) − 0.619?

It is Muskat's solution for the pressure drop between an injector and producer in an infinite repeated five-spot.

What do the defaults represent?

An illustrative case: 40-acre five-spot, 25 ft of 120 mD sand. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 14, eqs. 14-71 to 14-74 and Example 14-12 (Muskat, 1948; Caudle and Witte, 1959)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.