FireCADCalc

Water Breakthrough Time Under Coning in a Vertical Well

Dimensionless cone height and time to water breakthrough in a vertical well with bottom water, and the critical rate, by two correlations.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Thick column, low rate, M = 0.8Viscous oil, M = 8

Accepted: 0.54344 to 543,440 bbl/d
Accepted: 1.6404 to 984.25 ft
Accepted: 0.32808 to 984.25 ft
Accepted: 56.185 to 81.156 lb/ft³
Accepted: 18.728 to 68.671 lb/ft³
Accepted: 0.01 to 1,000 cP
Accepted: 1 to 3
Accepted: 0.00010132 to 101,320 mD
Accepted: 1.013E-5 to 101,320 mD
Accepted: 1 to 50 %
Accepted: 0.01 to 10

Results

Bournazel–Jeanson predicts earlier breakthrough than Sobocinski–Cornelius; the two bracket field experience. Lower rates, shorter perforations at the top of the column, or a horizontal well delay breakthrough.

Dimensionless cone height0.082000
Dimensionless breakthrough time (Sobocinski–Cornelius)0.049642
Time to breakthrough (Sobocinski–Cornelius)50.649d
Dimensionless breakthrough time (Bournazel–Jeanson)0.027867
Time to breakthrough (Bournazel–Jeanson)28.432d
Critical rate (Sobocinski–Cornelius)9.4000bbl/d
Critical rate (Bournazel–Jeanson)7.6533bbl/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Thick column, low rate, M = 0.8. The inputs, in the units selected above:

InputValue
Oil rate120.00 bbl/d
Oil column thickness80.000 ft
Perforated interval20.000 ft
Water density64.000 lb/ft³
Oil density50.000 lb/ft³
Oil viscosity1.5000 cP
Oil formation volume factor1.2000 -
Horizontal permeability200.00 mD
Vertical permeability40.000 mD
Porosity20.000 %
Water-oil mobility ratio0.80000 -

Applying the formula below gives:

ResultValue
Dimensionless cone height3.0613
Dimensionless breakthrough time (Sobocinski–Cornelius)8.1250
Time to breakthrough (Sobocinski–Cornelius)3,735.9 d
Dimensionless breakthrough time (Bournazel–Jeanson)3.5719
Time to breakthrough (Bournazel–Jeanson)1,642.4 d
Critical rate (Sobocinski–Cornelius)105.28 bbl/d
Critical rate (Bournazel–Jeanson)85.717 bbl/d

Open this example in the calculator and change any input.

Formula

\(Z = \frac{0.492\times10^{-4}\Delta\rho\,k_hh(h - h_p)}{\mu_oB_oQ_o}, \quad (t_D)_{BT} = \frac{4Z + 1.75Z^2 - 0.75Z^3}{7 - 2Z}\ \text{or}\ \frac{Z}{3 - 0.7Z}, \quad t_{BT} = \frac{20{,}325\mu_oh\phi(t_D)_{BT}}{\Delta\rho\,k_v(1 + M^\alpha)}\)

Variables

Symbol Meaning SI unit
\(Q_o\) Oil rate m³/s
\(h\) Oil column thickness m
\(h_p\) Perforated interval m
\(\rho_w\) Water density kg/m³
\(\rho_o\) Oil density kg/m³
\(\mu_o\) Oil viscosity Pa·s
\(B_o\) Oil formation volume factor -
\(k_h\) Horizontal permeability m²
\(k_v\) Vertical permeability m²
\(\phi\) Porosity -
\(M\) Water-oil mobility ratio -
\(Z\) Dimensionless cone height -
\((t_D)_{BT,SC}\) Dimensionless breakthrough time (Sobocinski–Cornelius) -
\(t_{BT,SC}\) Time to breakthrough (Sobocinski–Cornelius) s
\((t_D)_{BT,BJ}\) Dimensionless breakthrough time (Bournazel–Jeanson) -
\(t_{BT,BJ}\) Time to breakthrough (Bournazel–Jeanson) s
\(Q_{oc,SC}\) Critical rate (Sobocinski–Cornelius) m³/s
\(Q_{oc,BJ}\) Critical rate (Bournazel–Jeanson) m³/s

Method and standards

Sobocinski–Cornelius and Bournazel–Jeanson (field units).

Where it is used

  • Completion and rate planning in bottom-water reservoirs.
  • Comparing vertical and horizontal wells.

Common mistakes

  • Using k_h instead of k_v in the time equation.
  • Measuring h_p from the bottom.

Assumptions and limits

  • Homogeneous anisotropic reservoir; constant rate.

Questions and answers

Why does vertical permeability control breakthrough?

The cone grows by vertical flow of water up toward the perforations; low k_v slows it down.

What does Z ≥ 3.5 mean?

At that dimensionless cone height the cone is stable and never reaches the well; the rate that gives Z = 3.5 is the critical rate.

What do the defaults represent?

An illustrative case: Thick column, low rate, M = 0.8. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 9, eqs. 9-21 to 9-27 and Examples 9-11 to 9-13

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.