FireCADCalc

Schilthuis Water Influx Rate and Influx Constant

Rate of water influx from reservoir voidage at stabilised pressure, Schilthuis's steady-state influx constant, and cumulative influx at that pressure drop.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Field with water productionUndersaturated oil, GOR = Rs

Accepted: 0 to 5,434,400 bbl/d
Accepted: 1 to 3
Accepted: 0 to 11,229 scf/STB
Accepted: 0 to 11,229 scf/STB
Accepted: 1.781E-5 to 0.17811 bbl/scf
Accepted: 0 to 5,434,400 bbl/d
Accepted: 0.9 to 1.2
Accepted: 14.504 to 14,504 psi
Accepted: 14.504 to 14,504 psi
Accepted: 0 to 115,740 d

Results

At stabilised pressure the influx equals the reservoir voidage. A constant C over the history confirms a steady-state aquifer; a falling C points to an unsteady (van Everdingen–Hurst) aquifer. For a varying pressure, W_e = C∫(p_i − p)dt.

Water influx rate (reservoir voidage)21,012bbl/d
Water influx constant84.048bbl/(d·psi)
Cumulative influx over the time at this drop1.5339e+07bbl

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Field with water production. The inputs, in the units selected above:

InputValue
Oil rate (stock tank)8,500.0 bbl/d
Oil formation volume factor1.2500 -
Producing gas-oil ratio650.00 scf/STB
Solution gas-oil ratio520.00 scf/STB
Gas formation volume factor0.001100 bbl/scf
Water rate (stock tank)3,000.0 bbl/d
Water formation volume factor1.0200 -
Initial reservoir pressure2,800.0 psi
Stabilised reservoir pressure2,450.0 psi
Time at this pressure drop (for cumulative influx)180.00 d

Applying the formula below gives:

ResultValue
Water influx rate (reservoir voidage)14,901 bbl/d
Water influx constant42.573 bbl/(d·psi)
Cumulative influx over the time at this drop2,682,090 bbl

Open this example in the calculator and change any input.

Formula

\(e_w = Q_oB_o + (GOR - R_s)Q_oB_g + Q_wB_w, \quad C = \frac{e_w}{p_i - p}, \quad W_e = C\int(p_i - p)\,dt\)

Variables

Symbol Meaning SI unit
\(Q_o\) Oil rate (stock tank) m³/s
\(B_o\) Oil formation volume factor -
\(GOR\) Producing gas-oil ratio m³/m³
\(R_s\) Solution gas-oil ratio m³/m³
\(B_g\) Gas formation volume factor m³/m³
\(Q_w\) Water rate (stock tank) m³/s
\(B_w\) Water formation volume factor -
\(p_i\) Initial reservoir pressure Pa
\(p\) Stabilised reservoir pressure Pa
\(t\) Time at this pressure drop (for cumulative influx) s
\(e_w\) Water influx rate (reservoir voidage) m³/s
\(C\) Water influx constant m³/(s·Pa)
\(W_e\) Cumulative influx over the time at this drop m³

Method and standards

Schilthuis steady-state aquifer.

Where it is used

  • Water-drive reservoir studies.
  • Checking aquifer models against history.

Common mistakes

  • Using a pressure that is not stabilised.
  • Mixing reservoir and stock-tank volumes.

Assumptions and limits

  • Steady-state aquifer flow; stabilised pressure.

Questions and answers

Why does voidage equal influx?

If the reservoir pressure is steady, whatever leaves the pore space (oil, free gas, water) must be replaced by water coming in.

What is free gas production?

Gas produced above the solution gas, (GOR − R_s)Q_o, occupying B_g reservoir barrels per scf.

What do the defaults represent?

An illustrative case: Field with water production. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 10, eqs. 10-1, 10-8 to 10-10 and Example 10-3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.