Transient Pressure Around a Well: Line-Source Ei Solution

Pressure at a radius and time around a well producing at constant rate in an infinite-acting reservoir (Ei line source), log approximation and stabilisation time.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Oil well 400 STB/d, 0.3 ft wellbore, after 5 h

Accepted: 0 to 543,440 bbl/d
Accepted: 1 to 3
Accepted: 0.01 to 1,000 cP
Accepted: 0.0010132 to 10,132 mD
Accepted: 0.32808 to 1,640.4 ft
Accepted: 1 to 50 %
Accepted: 6.895E-8 to 0.0068948 1/psi
Accepted: 14.504 to 14,504 psi
Accepted: 0.098425 to 32,808 ft
Accepted: 0.00027778 to 277,780 h
Accepted: 0.24711 to 24,711 acre

Results

x < 0.01: the logarithmic (semilog) approximation is valid here.

Argument x = φμc_tr²/(4kt)4.6079e-07
Exponential integral E₁(x)14.013
Pressure at r and t3,443.8psi
Pressure drop356.17psi
Pressure by the log approximation3,443.8psi
Time to pseudo-steady state (circular area)26.763h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Oil well 400 STB/d, 0.3 ft wellbore, after 5 h. The inputs, in the units selected above:

InputValue
Oil rate (stock tank)400.00 bbl/d
Oil formation volume factor1.2000 -
Oil viscosity1.2000 cP
Permeability80.000 mD
Net pay thickness20.000 ft
Porosity18.000 %
Total compressibility1.0000e-05 1/psi
Initial reservoir pressure3,800.0 psi
Radius from the well (the wellbore radius for p_wf)0.30000 ft
Time since the start of flow5.0000 h
Drainage area (for the stabilisation time)60.000 acre

Applying the formula below gives:

ResultValue
Argument x = φμc_tr²/(4kt)4.6079e-07
Exponential integral E₁(x)14.013
Pressure at r and t3,443.8 psi
Pressure drop356.17 psi
Pressure by the log approximation3,443.8 psi
Time to pseudo-steady state (circular area)26.763 h

Open this example in the calculator and change any input.

Formula

\(p(r,t) = p_i - \frac{q_oB_o\mu_o}{4\pi kh}E_1(x), \quad x = \frac{\phi\mu c_t r^2}{4kt}, \quad E_1(x) \approx -\ln(1.781x)\ (x < 0.01), \quad t_{pss} = 0.1\frac{\phi\mu c_tA}{k}\)

Variables

Symbol Meaning SI unit
\(q_o\) Oil rate (stock tank) m³/s
\(B_o\) Oil formation volume factor -
\(\mu_o\) Oil viscosity Pa·s
\(k\) Permeability m²
\(h\) Net pay thickness m
\(\phi\) Porosity -
\(c_t\) Total compressibility 1/Pa
\(p_i\) Initial reservoir pressure Pa
\(r\) Radius from the well (the wellbore radius for p_wf) m
\(t\) Time since the start of flow s
\(A\) Drainage area (for the stabilisation time) m²
\(x\) Argument x = φμc_tr²/(4kt) -
\(-Ei(-x)\) Exponential integral E₁(x) -
\(p(r,t)\) Pressure at r and t Pa
\(p_i - p\) Pressure drop Pa
\(p_{log}\) Pressure by the log approximation Pa
\(t_{pss}\) Time to pseudo-steady state (circular area) s

Method and standards

Constant-rate line-source solution of the diffusivity equation.

Where it is used

  • Interference and drawdown test design.
  • Pressure profile around a producer.

Common mistakes

  • Using it after boundary effects start.
  • Using the log approximation at large x.

Assumptions and limits

  • Infinite-acting, homogeneous reservoir; slightly compressible fluid; no skin.

Questions and answers

When does the line-source solution apply?

While the reservoir is infinite acting, before the pressure disturbance reaches a boundary, and outside a few wellbore radii unless the wellbore radius is used for p_wf.

Why is most of the drop near the well?

The pressure varies with ln r: the first few feet carry as much drop as the next thousand.

What do the defaults represent?

An illustrative case: Oil well 400 STB/d, 0.3 ft wellbore, after 5 h. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-78 to 6-82 and Example 6-9; ch. 13 (stabilisation time), Abramowitz and Stegun, Handbook of Mathematical Functions, 5.1 (E₁ by series and continued fraction)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.