FireCADCalc

Fractional Flow of Water (Water Cut) in a Waterflood

Reservoir water cut from relative permeabilities and viscosities, with the gravity term for dipping beds, and the matching reservoir and surface water-oil ratios.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Sw 0.55, 3 cP oil, 5 degrees up-dip

Accepted: 0 to 1
Accepted: 1E-6 to 1
Accepted: 0.01 to 10,000 cP
Accepted: 0.01 to 1,000 cP
Accepted: 0.0010132 to 10,132 mD
Accepted: 10.764 to 107,640,000 ft²
Accepted: 0.00054344 to 5,434,400 bbl/d
Accepted: 56.185 to 81.156 lb/ft³
Accepted: 18.728 to 68.671 lb/ft³
Accepted: -90 to 90 °
Accepted: 1 to 3
Accepted: 0.9 to 1.2

Results

Capillary pressure gradient neglected. Injecting down-dip so that water moves up-dip lowers the water cut; injecting up-dip raises it. Repeat at several saturations to draw the fractional flow curve.

Water cut, horizontal (no gravity)70.588%
Water cut with gravity (reservoir)70.474%
Oil cut (reservoir)29.526%
Water-oil ratio (reservoir)2.3868
Water-oil ratio (surface)2.7278
Surface water cut73.175%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sw 0.55, 3 cP oil, 5 degrees up-dip. The inputs, in the units selected above:

InputValue
Oil relative permeability at the saturation0.30000 -
Water relative permeability at the saturation0.12000 -
Oil viscosity3.0000 cP
Water viscosity0.50000 cP
Absolute permeability50.000 mD
Cross-sectional area of the flood25,000 ft²
Water injection rate (reservoir)1,000.0 bbl/d
Water density64.000 lb/ft³
Oil density45.000 lb/ft³
Dip angle (positive: injector down-dip, flood moving up-dip)5.0000 °
Oil formation volume factor1.2000 -
Water formation volume factor1.0500 -

Applying the formula below gives:

ResultValue
Water cut, horizontal (no gravity)70.588 %
Water cut with gravity (reservoir)70.474 %
Oil cut (reservoir)29.526 %
Water-oil ratio (reservoir)2.3868
Water-oil ratio (surface)2.7278
Surface water cut73.175 %

Open this example in the calculator and change any input.

Formula

\(f_w = \frac{1 - \frac{kk_{ro}A}{\mu_oi_w}(\rho_w - \rho_o)g\sin\alpha}{1 + \frac{k_{ro}}{k_{rw}}\frac{\mu_w}{\mu_o}}, \quad WOR_s = \frac{B_of_w}{B_w(1 - f_w)}\)

Variables

Symbol Meaning SI unit
\(k_{ro}\) Oil relative permeability at the saturation -
\(k_{rw}\) Water relative permeability at the saturation -
\(\mu_o\) Oil viscosity Pa·s
\(\mu_w\) Water viscosity Pa·s
\(k\) Absolute permeability m²
\(A\) Cross-sectional area of the flood m²
\(i_w\) Water injection rate (reservoir) m³/s
\(\rho_w\) Water density kg/m³
\(\rho_o\) Oil density kg/m³
\(\alpha\) Dip angle (positive: injector down-dip, flood moving up-dip) rad
\(B_o\) Oil formation volume factor -
\(B_w\) Water formation volume factor -
\(f_{w,0}\) Water cut, horizontal (no gravity) -
\(f_w\) Water cut with gravity (reservoir) -
\(f_o\) Oil cut (reservoir) -
\(WOR_r\) Water-oil ratio (reservoir) -
\(WOR_s\) Water-oil ratio (surface) -
\(f_{ws}\) Surface water cut -

Method and standards

Fractional flow equation (Leverett).

Where it is used

  • Waterflood design and forecasts.
  • Choosing injection direction and rate.

Common mistakes

  • Using stock-tank instead of reservoir rates.
  • Using the wrong sign of the dip.

Assumptions and limits

  • Linear displacement; capillary pressure neglected.

Questions and answers

Why does oil viscosity matter so much?

Water cut depends on the mobility ratio; a viscous oil lets water finger through, so the cut rises early and recovery at breakthrough falls.

Is the gravity effect large?

Usually a few per cent at normal injection rates; it matters at low rates and steep dips.

What do the defaults represent?

An illustrative case: Sw 0.55, 3 cP oil, 5 degrees up-dip. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 14, eqs. 14-22 to 14-31 and Examples 14-5 and 14-6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.