Worked example
Example: Gas-free oil well, 45 psi per cycle. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Constant oil rate during the test | 600.00 bbl/d |
| Oil formation volume factor | 1.3000 - |
| Oil viscosity | 0.80000 cP |
| Net pay thickness | 40.000 ft |
| Slope of the semilog straight line (per log cycle) | 45.000 psi |
| Initial reservoir pressure | 3,800.0 psi |
| Pressure on the straight line at 1 hour | 3,420.0 psi |
| Porosity | 18.000 % |
| Total compressibility | 1.4000e-05 1/psi |
| Wellbore radius | 0.35400 ft |
Applying the formula below gives:
| Result | Value |
|---|---|
| Permeability | 56.357 mD |
| Skin factor | 3.8264 |
| Pressure drop due to skin | 149.56 psi |
| Radius reached by the pressure disturbance after 1 hour | 171.71 ft |
Open this example in the calculator and change any input.
Formula
\(k = \frac{Q_oB_o\mu_o\ln10}{4\pi|m|h}, \quad s = 1.1513\left[\frac{p_i - p_{1hr}}{|m|} - \log\frac{4k(1\,\text{h})}{\gamma\phi\mu c_tr_w^2}\right], \quad \Delta p_{skin} = 0.869|m|s\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_o\) | Constant oil rate during the test | m³/s |
| \(B_o\) | Oil formation volume factor | - |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(h\) | Net pay thickness | m |
| \(|m|\) | Slope of the semilog straight line (per log cycle) | Pa |
| \(p_i\) | Initial reservoir pressure | Pa |
| \(p_{1hr}\) | Pressure on the straight line at 1 hour | Pa |
| \(\phi\) | Porosity | - |
| \(c_t\) | Total compressibility | 1/Pa |
| \(r_w\) | Wellbore radius | m |
| \(k\) | Permeability | m² |
| \(s\) | Skin factor | - |
| \(\Delta p_{skin}\) | Pressure drop due to skin | Pa |
| \(r_{inv}(1\,\text{h})\) | Radius reached by the pressure disturbance after 1 hour | m |
Method and standards
Semilog drawdown analysis.
Where it is used
- Well test interpretation.
- Checking completion damage.
Common mistakes
- Fitting the line through storage-dominated data.
- Using a rate that varied during the test.
Assumptions and limits
- Infinite-acting radial flow; constant rate.
Questions and answers
How does a drawdown test differ from a build-up?
The well flows at constant rate from shut-in conditions and the falling pressure is analysed; it gives the same k and s but needs a truly constant rate, which is hard to hold.
What is the radius of investigation?
How far the pressure disturbance has travelled, r ≈ √(4kt/φμc_t); it grows with the square root of time.
What do the defaults represent?
An illustrative case: Gas-free oil well, 45 psi per cycle. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-170 to 6-174 and Example 6-24 (Earlougher's drawdown)