Worked example
Example: Phenol (Perry's example: 350.84 K). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Carbon atoms | 6.0000 - |
| Hydrogen atoms | 6.0000 - |
| Oxygen atoms | 1.0000 - |
| Sulfur and silicon atoms | 0 - |
| Halogen atoms | 0 - |
| Vapour pressure A (ln p/Pa = A + B/T + C ln T + D T^E) | 95.444 - |
| B (K) | -10,113 - |
| C | -10.090 - |
| D | 6.7603e-18 - |
| E | 6.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Moles of O₂ per mole of fuel | 7.0000 |
| Vapour pressure at the flash point | 1.8094 kPa |
| Flash point | 77.689 °C |
| Stoichiometric vapour concentration in air | 2.9060 % |
Open this example in the calculator and change any input.
Formula
\(p^*(T_{FP}) = \frac{1\ \mathrm{atm}}{8\beta}, \quad \beta = N_C + N_{Si} + N_S + \frac{N_H - N_X - 2N_O}{4}, \quad C_{st} = \frac{1}{1 + 4.773\beta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N_C\) | Carbon atoms | - |
| \(N_H\) | Hydrogen atoms | - |
| \(N_O\) | Oxygen atoms | - |
| \(N_S + N_{Si}\) | Sulfur and silicon atoms | - |
| \(N_X\) | Halogen atoms | - |
| \(A\) | Vapour pressure A (ln p/Pa = A + B/T + C ln T + D T^E) | - |
| \(B\) | B (K) | - |
| \(C\) | C | - |
| \(D\) | D | - |
| \(E\) | E | - |
| \(\beta\) | Moles of O₂ per mole of fuel | - |
| \(p^*\) | Vapour pressure at the flash point | Pa |
| \(T_{FP}\) | Flash point | K |
| \(C_{st}\) | Stoichiometric vapour concentration in air | - |
Method and standards
Leslie–Geniesse with the user's vapour-pressure equation.
Where it is used
- Screening solvent hazards.
- Checking supplier flash points.
Common mistakes
- Using open-cup data for comparison.
- A vapour-pressure equation fitted far from the flash point.
Assumptions and limits
- Organic compounds; closed cup.
- The vapour-pressure equation's own temperature range is not an input, so the result is not checked against it: confirm the flash point lies inside it.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2
- Eqs. (2-122)
- (2-123) and (2-128) (Leslie and Geniesse, International Critical Tables) with the phenol example
Questions and answers
What does Perry's example give?
Phenol (β = 7): 350.84 K, 0.4 % below the DIPPR value of 352.15 K.
Why 1/(8β)?
At the flash point the vapour is roughly at the lower flammability limit, which for many organics is about half the stoichiometric concentration; Leslie and Geniesse put it at 1/(8β) atm.
What vapour-pressure equation is used?
ln p = A + B/T + C ln T + D Tᴱ (the DIPPR form, p in Pa). For Antoine constants set C = D = 0 and adjust.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.