FireCADCalc

Liquid Viscosity–Temperature Fit (Andrade Equation)

Andrade constants ln μ = A + B/T from a liquid's viscosity at two temperatures, and the viscosity at a third temperature.

Inputs

Examples: Illustrative water, 20 and 50 CGlycolLight oil

Accepted: 0.001 to 100,000,000 cP
Accepted: -123.15 to 526.85 °C
Accepted: 0.001 to 100,000,000 cP
Accepted: -123.15 to 526.85 °C
Accepted: -123.15 to 526.85 °C

Results

Andrade's equation ln μ = A + B/T fits most liquids over moderate ranges, giving a straight line of ln μ against 1/T. Interpolating between the two data points is reliable; extrapolating far beyond them is not, especially near the freezing point or for oils, whose viscosity follows a double-logarithmic (Walther) law better.

Constant A (μ in Pa·s)-12.496
Constant B2,905.0K
Viscosity at the temperature wanted17.776cP
Apparent activation energy of flow B·R24.154kJ/mol

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative water, 20 and 50 C. The inputs, in the units selected above:

InputValue
Viscosity at the first temperature1.0000 cP
First temperature20.000 °C
Viscosity at the second temperature0.54700 cP
Second temperature50.000 °C
Temperature wanted40.000 °C

Applying the formula below gives:

ResultValue
Constant A (μ in Pa·s)-13.406
Constant B1,905.1 K
Viscosity at the temperature wanted0.66031 cP
Apparent activation energy of flow B·R15.840 kJ/mol

Open this example in the calculator and change any input.

Formula

\(\ln\mu = A + \frac{B}{T}, \quad B = \frac{\ln(\mu_1/\mu_2)}{1/T_1 - 1/T_2}\)

Variables

Symbol Meaning SI unit
\(\mu_1\) Viscosity at the first temperature Pa·s
\(T_1\) First temperature K
\(\mu_2\) Viscosity at the second temperature Pa·s
\(T_2\) Second temperature K
\(T\) Temperature wanted K
\(A\) Constant A (μ in Pa·s) -
\(B\) Constant B K
\(\mu\) Viscosity at the temperature wanted Pa·s
\(E_\mu\) Apparent activation energy of flow B·R J/mol

Method and standards

Andrade equation.

Where it is used

  • Pump and pipe calculations at other temperatures.
  • Filling gaps in property data.

Common mistakes

  • Using °C instead of kelvin.
  • Extrapolating far beyond the data.

Assumptions and limits

  • Two-constant fit; Newtonian liquid.

References

  • Andrade (Arrhenius-type) liquid viscosity correlation

Questions and answers

How do I find viscosity at another temperature from two points?

Fit ln μ = A + B/T through the two points and evaluate it at the new temperature.

Does it work for fuel oil?

Roughly; the Walther (ASTM D341) form is better for petroleum oils.

What do the defaults represent?

Water: 1.00 cP at 20 °C and 0.547 cP at 50 °C, evaluated at 40 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Perry's Chemical Engineers' Handbook, 8th ed. (McGraw-Hill, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.