Worked example
Example: Illustrative 1.5 m3/h TEG, 50 kg/h water. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Glycol circulation | 1.5000 m³/h |
| Rich glycol density | 1,110.0 kg/m³ |
| Glycol specific heat | 2.5000 kJ/(kg·K) |
| Rich glycol temperature to the reboiler | 150.00 °C |
| Reboiler temperature | 204.00 °C |
| Water removed | 50.000 kg/h |
| Heat to vaporise water (incl. desorption) | 2,480.0 kJ/kg |
| Reflux ratio (water refluxed per water removed) | 0.25000 - |
| Heat losses | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Sensible heat | 62.438 kW |
| Water vaporisation | 34.444 kW |
| Reflux duty | 8.6111 kW |
| Reboiler duty | 117.21 kW |
| Duty per litre of glycol circulated (kJ/L) | 281.31 |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \frac{\dot V_g\rho c_p(T_r - T_{in}) + \dot m_wh_{fg}(1 + r)}{1 - f_L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_g\) | Glycol circulation | m³/s |
| \(\rho_g\) | Rich glycol density | kg/m³ |
| \(c_{p,g}\) | Glycol specific heat | J/(kg·K) |
| \(T_{in}\) | Rich glycol temperature to the reboiler | K |
| \(T_r\) | Reboiler temperature | K |
| \(\dot m_w\) | Water removed | kg/s |
| \(h_{fg}\) | Heat to vaporise water (incl. desorption) | J/kg |
| \(r\) | Reflux ratio (water refluxed per water removed) | - |
| \(f_L\) | Heat losses | - |
| \(\dot Q_s\) | Sensible heat | W |
| \(\dot Q_v\) | Water vaporisation | W |
| \(\dot Q_r\) | Reflux duty | W |
| \(\dot Q\) | Reboiler duty | W |
| \(\dot Q/\dot V_g\) | Duty per litre of glycol circulated (kJ/L) | - |
Method and standards
Reboiler duty.
Where it is used
- Dehydration unit design and debottlenecking.
- Fuel gas use estimates.
Common mistakes
- Forgetting reflux and losses.
- Using lean instead of rich glycol flow.
Assumptions and limits
- Steady state; constant properties.
References
- Glycol regenerator heat balance
Questions and answers
What reboiler temperature is used?
About 200–204 °C; higher temperatures give leaner glycol but degrade TEG.
How can duty be reduced?
Preheat rich glycol against hot lean glycol and avoid over-circulating.
What do the defaults represent?
An illustrative 1.5 m³/h TEG at 1,110 kg/m³ heated from 150 to 204 °C, removing 50 kg/h of water with 25 % reflux and 10 % losses.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
GPSA Engineering Data Book, 12th ed. (Gas Processors Suppliers Association, 2004), Kohl and Nielsen, Gas Purification, 5th ed. (Gulf, 1997)