FireCADCalc

Gas Well Liquid Loading: Turner Critical Rate

Minimum gas rate to lift liquid droplets out of a gas well (Turner), from pressure, temperature, tubing size, liquid density and surface tension.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Condensate at 300 psia wellhead, 2 3/8 in tubingWater at 2500 psia bottom-hole, 2 7/8 in tubing

Accepted: 14.504 to 14,504 psi
Accepted: -9.67 to 440.33 °F
Accepted: 0.3937 to 11.811 in
Accepted: 24.971 to 74.914 lb/ft³
Accepted: 1 to 100 mN/m
Accepted: 0.55 to 1.5

Results

Check at the wellhead and at the bottom of the tubing and use the larger rate. Below the critical rate droplets fall back, liquid accumulates and the well loads up; smaller tubing, a velocity string or plunger lift raise the gas velocity.

Gas compressibility factor (Hall–Yarborough)0.94068
Gas density1.1156lb/ft³
Critical (terminal) velocity with Turner's 20 % margin9.8529ft/s
Minimum gas rate to unload liquids387.61Mscf/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Condensate at 300 psia wellhead, 2 3/8 in tubing. The inputs, in the units selected above:

InputValue
Flowing pressure at the point checked (absolute)300.00 psi
Temperature at that point80.330 °F
Tubing inside diameter1.9950 in
Liquid density (water about 67, condensate about 45 lb/ft³)45.000 lb/ft³
Gas-liquid surface tension20.000 mN/m
Gas gravity (air = 1)0.70000 -

Applying the formula below gives:

ResultValue
Gas compressibility factor (Hall–Yarborough)0.94068
Gas density1.1156 lb/ft³
Critical (terminal) velocity with Turner's 20 % margin9.8529 ft/s
Minimum gas rate to unload liquids387.61 Mscf/d

Open this example in the calculator and change any input.

Formula

\(v_t = 1.912\frac{[\sigma(\rho_L - \rho_g)]^{1/4}}{\rho_g^{1/2}}\ (\text{ft/s}), \quad Q_{min} = \frac{128\,r^2p\,[\sigma(\rho_L - \rho_g)]^{1/4}}{TZ\sqrt{\rho_g}}\ (\text{Mscf/d; in, psia, °R, dyn/cm, lb/ft}^3)\)

Variables

Symbol Meaning SI unit
\(p\) Flowing pressure at the point checked (absolute) Pa
\(T\) Temperature at that point K
\(d\) Tubing inside diameter m
\(\rho_L\) Liquid density (water about 67, condensate about 45 lb/ft³) kg/m³
\(\sigma\) Gas-liquid surface tension N/m
\(\gamma_g\) Gas gravity (air = 1) -
\(Z\) Gas compressibility factor (Hall–Yarborough) -
\(\rho_g\) Gas density kg/m³
\(v_t\) Critical (terminal) velocity with Turner's 20 % margin m/s
\(Q_{min}\) Minimum gas rate to unload liquids Nm³/s

Method and standards

Turner droplet model with 20 % margin.

Where it is used

  • Velocity string and tubing design.
  • Deciding when to install artificial lift on gas wells.

Common mistakes

  • Using the bottom-hole value only.
  • Using the casing instead of the tubing diameter.

Assumptions and limits

  • Droplet model; mist flow.

Questions and answers

Why is water harder to lift than condensate?

It is denser and has a higher surface tension, so its largest stable droplets are bigger and need a faster gas stream.

Where should I check?

Usually at the wellhead (lowest pressure, highest velocity is not guaranteed); Turner's original work found the wellhead governs in most wells.

What do the defaults represent?

An illustrative case: Condensate at 300 psia wellhead, 2 3/8 in tubing. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 8, eq. 8-61 and Example 8-10 (Turner, Hubbard and Dukler, 1969), Hall and Yarborough (1973) Z-factor equation (engine)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.