FireCADCalc

Gas Pipeline Blowdown Time (AGA Formula)

Time to blow down a closed section of gas pipeline through a blowdown pipe, from pressure, gas gravity, pipe and blowdown diameters, length and choke factor.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: NPS 36 line, 12 miles, NPS 8 venturi plugNPS 12 lateral, 2 miles, NPS 4 ideal nozzle

Accepted: 14.504 to 2,900.8 psi
Accepted: 0.5 to 1.5
Accepted: 0.7874 to 78.74 in
Accepted: 0.0062137 to 124.27 mi
Accepted: 0.3937 to 39.37 in

Results

Empirical AGA formula in common practice; the SI form T = 0.0192 P₁^{1/3} G^{1/2} D² L F_c/d² (kPa, mm, km) is identical. Gas exits to atmosphere; noise and the vent stack are not considered.

Blowdown time7.4790min
Geometric volume of the section234.85m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: NPS 36 line, 12 miles, NPS 8 venturi plug. The inputs, in the units selected above:

InputValue
Initial pressure (absolute)1,100.0 psi
Gas gravity (air = 1)0.58000 -
Pipeline inside diameter34.500 in
Length of the isolated section12.000 mi
Blowdown pipe inside diameter7.9810 in
Choke factor of the blowdown valveVenturi lubricated plug (3.2)

Applying the formula below gives:

ResultValue
Blowdown time331.70 min
Geometric volume of the section11,647 m³

Open this example in the calculator and change any input.

Formula

\(T = 0.0588\,\frac{P_1^{1/3}G^{1/2}D^2LF_c}{d^2}\ \ (\text{min; psia, in, mi})\)

Variables

Symbol Meaning SI unit
\(P_1\) Initial pressure (absolute) Pa
\(G\) Gas gravity (air = 1) -
\(D\) Pipeline inside diameter m
\(L\) Length of the isolated section m
\(d\) Blowdown pipe inside diameter m
\(F_c\) Choke factor of the blowdown valve -
\(T\) Blowdown time s
\(V\) Geometric volume of the section m³

Method and standards

AGA empirical blowdown formula.

Where it is used

  • Sizing blowdown assemblies at mainline valves.
  • Planning maintenance depressurisation.

Common mistakes

  • Using gauge pressure.
  • Using the nominal pipe size instead of the inside diameter.

Assumptions and limits

  • Empirical; choked flow through the blowdown pipe for most of the time.

Questions and answers

Why does the time grow with D²/d²?

The gas to be vented scales with the pipe cross-section; the outflow scales with the blowdown cross-section.

What is the choke factor?

It allows for the extra restriction of the valve type compared with an ideal nozzle; a lubricated plug valve slows blowdown about twice.

What do the defaults represent?

An illustrative case: NPS 36 line, 12 miles, NPS 8 venturi plug. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Menon, Gas Pipeline Hydraulics (CRC Press, 2005), sec. 6.10, eqs. 6.9 and 6.10 and Example 4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.