Worked example
Example: 50 MMscfd at 1,000 psia, condensate. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow (standard) | 50.000 MMscfd |
| Operating pressure (absolute) | 1,000.00 psi |
| Operating temperature | 26.667 °C |
| Compressibility factor | 0.88000 - |
| Gas specific gravity | 0.65000 - |
| Liquid density | 800.00 kg/m³ |
| Service | General separator with mist pad |
| Liquid flow | 10.000 m³/h |
| Liquid retention time | 3.0000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas density at operating conditions | 59.174 kg/m³ |
| Souders–Brown coefficient | 0.079696 m/s |
| Allowable gas velocity | 0.28199 m/s |
| Actual gas flow | 792.29 m³/h |
| Minimum separator inside diameter | 996.85 mm |
| Liquid hold-up volume | 0.50000 m³ |
Open this example in the calculator and change any input.
Formula
\(V_{max} = K_{SB}\sqrt{\frac{\rho_L - \rho_G}{\rho_G}}, \quad K_{SB} = 0.35 - 0.0001(P_{psig} - 100)\ \text{ft/s}, \quad D = \sqrt{\frac{4Q_a}{\pi V_{max}}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_g\) | Gas flow (standard) | Nm³/s |
| \(P\) | Operating pressure (absolute) | Pa |
| \(T\) | Operating temperature | K |
| \(Z\) | Compressibility factor | - |
| \(SG\) | Gas specific gravity | - |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(\text{service}\) | Service | - |
| \(Q_L\) | Liquid flow | m³/s |
| \(t_r\) | Liquid retention time | s |
| \(\rho_G\) | Gas density at operating conditions | kg/m³ |
| \(K_{SB}\) | Souders–Brown coefficient | m/s |
| \(V_{max}\) | Allowable gas velocity | m/s |
| \(Q_a\) | Actual gas flow | m³/s |
| \(D\) | Minimum separator inside diameter | m |
| \(V_L\) | Liquid hold-up volume | m³ |
Method and standards
Souders–Brown with the GPSA K fit.
Where it is used
- Inlet separators, scrubbers and knockout drums.
- Fuel gas conditioning skids.
Common mistakes
- Using standard instead of actual gas flow.
- Leaving out the service reduction for glycol or scrubbers.
Assumptions and limits
- Vertical vessel with mist pad; gas capacity only.
References
- Mokhatab
- Poe and Speight
- Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
- ch. 5
- eqs. 5-6 to 5-8 (Souders and Brown; GPSA K factor fit)
Questions and answers
What sets the diameter?
The gas velocity must stay below the speed at which droplets are carried up through the mist pad; that limit grows with the density difference.
Why does K fall with pressure?
At high pressure the gas is denser and the liquid surface tension lower, so droplets are smaller and harder to separate.
What do the defaults represent?
50 MMscfd of 0.65-gravity gas at 1,000 psia and 80 °F with 800 kg/m³ condensate, 10 m³/h for 3 minutes.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.