FireCADCalc

Gas–Liquid Separator Sizing by Souders–Brown

Allowable gas velocity and minimum diameter of a vertical gas–liquid separator from the Souders–Brown K factor, and the liquid hold-up volume for a retention time.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: 50 MMscfd at 1,000 psia, condensateCompressor suction scrubber, 300 psiaVacuum flash drum

Results

K is the GPSA mist-pad fit given by Mokhatab, with his service reductions; it is meant for pressures above about 100 psig. The diameter is the gas-capacity minimum: add nozzles, inlet device and mist-pad clearances, and check the liquid section.

Gas density at operating conditions14.967kg/m³
Souders–Brown coefficient0.075774m/s
Allowable gas velocity0.51263m/s
Actual gas flow896.35m³/h
Minimum separator inside diameter786.39mm
Liquid hold-up volume0.016667m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 MMscfd at 1,000 psia, condensate. The inputs, in the units selected above:

InputValue
Gas flow (standard)50.000 MMscfd
Operating pressure (absolute)1,000.00 psi
Operating temperature26.667 °C
Compressibility factor0.88000 -
Gas specific gravity0.65000 -
Liquid density800.00 kg/m³
ServiceGeneral separator with mist pad
Liquid flow10.000 m³/h
Liquid retention time3.0000 min

Applying the formula below gives:

ResultValue
Gas density at operating conditions59.174 kg/m³
Souders–Brown coefficient0.079696 m/s
Allowable gas velocity0.28199 m/s
Actual gas flow792.29 m³/h
Minimum separator inside diameter996.85 mm
Liquid hold-up volume0.50000 m³

Open this example in the calculator and change any input.

Formula

\(V_{max} = K_{SB}\sqrt{\frac{\rho_L - \rho_G}{\rho_G}}, \quad K_{SB} = 0.35 - 0.0001(P_{psig} - 100)\ \text{ft/s}, \quad D = \sqrt{\frac{4Q_a}{\pi V_{max}}}\)

Variables

Symbol Meaning SI unit
\(Q_g\) Gas flow (standard) Nm³/s
\(P\) Operating pressure (absolute) Pa
\(T\) Operating temperature K
\(Z\) Compressibility factor -
\(SG\) Gas specific gravity -
\(\rho_L\) Liquid density kg/m³
\(\text{service}\) Service -
\(Q_L\) Liquid flow m³/s
\(t_r\) Liquid retention time s
\(\rho_G\) Gas density at operating conditions kg/m³
\(K_{SB}\) Souders–Brown coefficient m/s
\(V_{max}\) Allowable gas velocity m/s
\(Q_a\) Actual gas flow m³/s
\(D\) Minimum separator inside diameter m
\(V_L\) Liquid hold-up volume m³

Method and standards

Souders–Brown with the GPSA K fit.

Where it is used

  • Inlet separators, scrubbers and knockout drums.
  • Fuel gas conditioning skids.

Common mistakes

  • Using standard instead of actual gas flow.
  • Leaving out the service reduction for glycol or scrubbers.

Assumptions and limits

  • Vertical vessel with mist pad; gas capacity only.

References

  • Mokhatab
  • Poe and Speight
  • Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
  • ch. 5
  • eqs. 5-6 to 5-8 (Souders and Brown; GPSA K factor fit)

Questions and answers

What sets the diameter?

The gas velocity must stay below the speed at which droplets are carried up through the mist pad; that limit grows with the density difference.

Why does K fall with pressure?

At high pressure the gas is denser and the liquid surface tension lower, so droplets are smaller and harder to separate.

What do the defaults represent?

50 MMscfd of 0.65-gravity gas at 1,000 psia and 80 °F with 800 kg/m³ condensate, 10 m³/h for 3 minutes.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.