FireCADCalc

Flare Thermal Radiation by the Point-Source Method

Radiant flux at a receptor from a flare by the point-source model, from flared mass rate, heating value, radiant fraction and geometry, and the safe distance.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 20 kg/s flareEmergency flare 100 kg/sSmall flare, continuous limit

Accepted: 36 to 3,600,000 kg/h
Accepted: 10 to 60 MJ/kg
Accepted: 5 to 50 %
Accepted: 50 to 100 %
Accepted: 1 to 300 m
Accepted: 0 to 2,000 m
Accepted: 0.5 to 20 kW/m²

Results

Point source: q = τFQ/(4πD²), D from the flame centre (stack tip plus about half the flame length, tilted by wind) to the receptor. F depends on the gas and flare type (roughly 0.1–0.3). Common limits: about 1.6 kW/m² for continuous exposure of people, 4.7 kW/m² for short emergency actions, 6.3 kW/m² for a few seconds; the user's design basis governs. A zero horizontal distance means the flame centre is above the allowable distance.

Heat release4,600.0MW
Distance from flame centre156.20m
Radiant flux at the receptor3.8256kW/m²
Distance for the allowable flux121.63m
Horizontal distance for the allowable flux69.232m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 kg/s flare. The inputs, in the units selected above:

InputValue
Flared gas mass rate72,000 kg/h
Lower heating value46.000 MJ/kg
Fraction of heat radiated25.000 %
Atmospheric transmissivity90.000 %
Height of flame centre above the receptor60.000 m
Horizontal distance to the receptor60.000 m
Allowable flux at the receptor4.7300 kW/m²

Applying the formula below gives:

ResultValue
Heat release920.00 MW
Distance from flame centre84.853 m
Radiant flux at the receptor2.2879 kW/m²
Distance for the allowable flux59.013 m
Horizontal distance for the allowable flux0 m

Open this example in the calculator and change any input.

Formula

\(q = \frac{\tau F\dot mLHV}{4\pi D^2}, \quad D_a = \sqrt{\frac{\tau F\dot Q}{4\pi q_a}}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Flared gas mass rate kg/s
\(LHV\) Lower heating value J/kg
\(F\) Fraction of heat radiated -
\(\tau\) Atmospheric transmissivity -
\(H_c\) Height of flame centre above the receptor m
\(x\) Horizontal distance to the receptor m
\(q_a\) Allowable flux at the receptor W/m²
\(\dot Q\) Heat release W
\(D\) Distance from flame centre m
\(q\) Radiant flux at the receptor W/m²
\(D_a\) Distance for the allowable flux m
\(x_a\) Horizontal distance for the allowable flux m

Method and standards

Flare radiation.

Where it is used

  • Flare stack height and sterile area.
  • Checking equipment and personnel exposure.

Common mistakes

  • Measuring distance from the stack base instead of the flame centre.
  • Ignoring wind tilt of the flame.

Assumptions and limits

  • Point source at the flame centre; isotropic radiation.

References

  • Point-source radiation model

Questions and answers

Why is the point-source model popular?

It is simple and conservative far from the flame, the region that sets sterile areas and stack heights.

What sets the radiant fraction?

Gas composition and flame type: heavier, sootier gases radiate more; high-velocity flare tips radiate less.

What do the defaults represent?

An illustrative 20 kg/s flare of 46 MJ/kg gas, F 0.25, τ 0.9, flame centre 60 m above a receptor 60 m away, 4.73 kW/m² allowable.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crowl and Louvar, Chemical Process Safety: Fundamentals with Applications, 3rd ed. (Prentice Hall, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.