FireCADCalc

Bakery Dough Water Temperature and Ice

Water temperature needed for a desired dough temperature from flour, room and preferment temperatures and mixer friction, and the ice to cool tap water to it.

Inputs

Examples: Illustrative straight doughWith a prefermentHot day, intensive mixer

Accepted: 10 to 40 °C
Accepted: -10 to 50 °C
Accepted: -10 to 50 °C
Accepted: 0 to 40 K
Accepted: -20 to 40 °C
Accepted: 0 to 50 °C
Accepted: 0 to 10,000 kg

Results

Bakers balance the temperatures that set the dough's final temperature: the desired dough temperature times the number of factors (three, or four with a preferment) less the flour, room, preferment temperatures and mixer friction gives the water temperature. Friction factors (about 10–15 °C for spiral mixers, more for intensive mixers) are found by measuring a batch. Where the water must be colder than tap water, part of it is replaced by ice, which absorbs about 80 °C worth of heat per kilogram as it melts.

The water would need to be below 0 °C: chill the flour, use flaked ice or reduce mixing.

Water temperature needed-4.0000°C
Factors counted3.0000
Ice (part of the water) to cool tap water16.071kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative straight dough. The inputs, in the units selected above:

InputValue
Desired dough temperature26.000 °C
Flour temperature22.000 °C
Room temperature25.000 °C
Mixer friction factor13.000 K
Preferment temperature (0 °C or below = none)0 °C
Tap water temperature28.000 °C
Water in the recipe10.000 kg

Applying the formula below gives:

ResultValue
Water temperature needed18.000 °C
Factors counted3.0000
Ice (part of the water) to cool tap water0.92593 kg

Open this example in the calculator and change any input.

Formula

\(T_w = nT_d - (T_f + T_r + \Delta T_m\ [+ T_p]), \quad m_i = m_w\frac{T_t - T_w}{T_t + 80}\)

Variables

Symbol Meaning SI unit
\(T_d\) Desired dough temperature K
\(T_f\) Flour temperature K
\(T_r\) Room temperature K
\(\Delta T_m\) Mixer friction factor K
\(T_p\) Preferment temperature (0 °C or below = none) K
\(T_t\) Tap water temperature K
\(m_w\) Water in the recipe kg
\(T_w\) Water temperature needed K
\(n\) Factors counted -
\(m_i\) Ice (part of the water) to cool tap water kg

Method and standards

Dough temperature.

Where it is used

  • Bakeries and biscuit plants.
  • Consistent fermentation.

Common mistakes

  • Leaving out the preferment factor.
  • Using an unmeasured friction factor.

Assumptions and limits

  • Temperatures in °C; similar heat capacities.

References

  • Bakers' desired dough temperature method

Questions and answers

What water temperature gives a 26 °C dough with 22 °C flour, 25 °C room and 13 °C friction?

18 °C; from 28 °C tap water, about 0.93 kg of every 10 kg should be ice.

Why include friction?

Mixing work heats the dough; intensive mixers add more.

What do the defaults represent?

An illustrative straight dough at 26 °C desired temperature, 22 °C flour, 25 °C room, 13 °C mixer friction, 28 °C tap water and 10 kg of water.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.