Worked example
Example: HTST 20 000 kg/h, 4 → 68 → 72 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Milk flow | 20,000 kg/h |
| Milk specific heat | 3.9300 kJ/(kg·K) |
| Raw milk in | 4.0000 °C |
| Milk leaving regeneration (heated side) | 68.000 °C |
| Pasteurisation temperature | 72.000 °C |
| Milk out after cooling | 4.0000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Regeneration efficiency | 94.118 % |
| Heat recovered | 1,397.3 kW |
| Heating duty | 87.333 kW |
| Cooling duty | 87.333 kW |
| Pasteurised milk leaving regeneration | 8.0000 °C |
Open this example in the calculator and change any input.
Formula
\(R = \frac{T_2 - T_1}{T_p - T_1}, \quad Q_h = \dot M c_p(T_p - T_2), \quad T_3 = T_p - (T_2 - T_1)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot M\) | Milk flow | kg/s |
| \(c_p\) | Milk specific heat | J/(kg·K) |
| \(T_1\) | Raw milk in | K |
| \(T_2\) | Milk leaving regeneration (heated side) | K |
| \(T_p\) | Pasteurisation temperature | K |
| \(T_o\) | Milk out after cooling | K |
| \(R\) | Regeneration efficiency | - |
| \(Q_r\) | Heat recovered | W |
| \(Q_h\) | Heating duty | W |
| \(Q_c\) | Cooling duty | W |
| \(T_3\) | Pasteurised milk leaving regeneration | K |
Method and standards
Energy balance with equal flows and specific heats on both sides.
Where it is used
- Pasteuriser design and audits.
Common mistakes
- Using different flows on both sides.
- Ignoring holding tube losses.
Assumptions and limits
- Equal mass flows and c_p; no losses.
- The cooled milk T_o must not exceed T₃. Regeneration above 95 % (a small approach T_p − T₂) is flagged: it needs a very large plate area.
References
- Mass and energy balances (definitions): regeneration efficiency = heat recovered / heat needed from raw-milk to pasteurisation temperature
Questions and answers
What is regeneration efficiency?
The temperature rise in regeneration as a share of the rise to pasteurisation temperature.
Why is high regeneration cheaper to run?
Hot pasteurised milk preheats the cold raw milk, cutting both heating and cooling.
What limits it?
Plate area and the pressure drop; 95 % needs a large regeneration section.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.