FireCADCalc

Cream Separator Fat Balance

Cream and skim milk flows from a separator from whole milk flow and the fat in milk, cream and skim, with the fat recovered in the cream (separation efficiency).

Food, dairy and textile

Inputs

Examples: 20 000 kg/h at 4 %, 40 % creamCold separation

Results

Cream1,977.5kg/h
Skim milk18,023kg/h
Fat recovered in the cream98.874%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 000 kg/h at 4 %, 40 % cream. The inputs, in the units selected above:

InputValue
Whole milk20,000 kg/h
Fat in the milk4.0000 %
Fat in the cream40.000 %
Fat in the skim0.050000 %

Applying the formula below gives:

ResultValue
Cream1,977.5 kg/h
Skim milk18,023 kg/h
Fat recovered in the cream98.874 %

Open this example in the calculator and change any input.

Formula

\(\dot M_c = \dot M\frac{f_m - f_s}{f_c - f_s}, \quad \eta = \frac{\dot M_c f_c}{\dot M f_m}\)

Variables

Symbol Meaning SI unit
\(\dot M\) Whole milk kg/s
\(f_m\) Fat in the milk -
\(f_c\) Fat in the cream -
\(f_s\) Fat in the skim -
\(\dot M_c\) Cream kg/s
\(\dot M_s\) Skim milk kg/s
\(\eta\) Fat recovered in the cream -

Method and standards

Total and fat balances.

Where it is used

  • Separator capacity checks.
  • Fat accounting.

Common mistakes

  • Using volume flow with mass fractions.
  • Ignoring sludge losses.

Assumptions and limits

  • Steady flow.

References

  • Mass and energy balances (definitions): total and fat balances

Questions and answers

What skim fat is good?

0.04–0.06 % for a well-run hermetic separator.

Why is efficiency below 100 %?

Fat lost in the skim; small globules escape separation.

Does temperature matter?

Warm separation (45–55 °C) gives lower skim fat than cold separation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.