Worked example
Example: 3 million L month. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Milk processed (or product) | 3,000.0 m³ |
| Steam used | 600.00 t |
| Fuel energy per kg of steam (on the fuel price's CV basis) | 3.2000 MJ/kg |
| Electricity used | 150,000 kWh |
| Water used | 4,500.0 m³ |
| Fuel price per GJ (your currency) | 800.00 - |
| Electricity price per kWh (your currency) | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam per m³ | 200.00 kg/m³ |
| Electricity per m³ | 50.000 kWh/m³ |
| Water per m³ of milk | 1.5000 m³/m³ |
| Energy cost per m³ (your currency) | 912.00 |
Open this example in the calculator and change any input.
Formula
\(s = \frac{m_s}{V}, \quad e_e = \frac{E_e}{V}, \quad w = \frac{V_w}{V}, \quad c = \frac{m_s\Delta h_s c_f + E_e c_e}{V}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Milk processed (or product) | m³ |
| \(m_s\) | Steam used | kg |
| \(\Delta h_s\) | Fuel energy per kg of steam | J/kg |
| \(E_e\) | Electricity used | J |
| \(V_w\) | Water used | m³ |
| \(c_f\) | Fuel price per GJ | - |
| \(c_e\) | Electricity price per kWh | - |
| \(s\) | Steam per m³ | kg/m³ |
| \(e_e\) | Electricity per m³ | J/m³ |
| \(w\) | Water per m³ of milk | m³/m³ |
| \(c\) | Energy cost per m³ | - |
Method and standards
KPI definitions.
Where it is used
- Monthly energy reporting.
- Benchmarking.
Common mistakes
- Mixing intake milk and product volumes.
- Ignoring CIP water.
Assumptions and limits
- Monthly totals.
- Fuel energy per kg of steam and the fuel price per GJ must be on the same calorific value basis (gross or net). Prices and the cost are in your own currency.
References
- Mass and energy balances (definitions): specific consumption definitions
Questions and answers
What water use is good for a dairy?
Below 1 L of water per litre of milk; many plants use 1.5–3.
Why per 1000 L?
It lets plants of different size be compared.
Why separate steam and electricity?
They cost very differently per kWh and have different saving measures.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.