Worked example
Example: 2 t/h bread, 10 % bake loss. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dough throughput | 2,000.0 kg/h |
| Dough specific heat | 2.8000 kJ/(kg·K) |
| Dough in | 30.000 °C |
| Crumb out | 98.000 °C |
| Bake loss (water evaporated) | 10.000 % |
| Tins or band heated | 1,500.0 kg/h |
| Tin specific heat | 0.48000 kJ/(kg·K) |
| Tin temperature rise | 150.00 K |
| Oven efficiency | 45.000 % |
| Fuel heating value | 46.000 MJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat to the dough | 105.78 kW |
| Heat to evaporate the bake loss | 125.85 kW |
| Heat to the tins | 30.000 kW |
| Fuel heat input | 581.40 kW |
| Fuel | 45.501 kg/h |
| Fuel per tonne of dough | 22.751 kg/t |
Open this example in the calculator and change any input.
Formula
\(Q = \frac{\dot Mc_p(T_2 - T_1) + \dot M b(\lambda + c_w(100 - T_2)) + \dot M_tc_t\Delta T_t}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot M\) | Dough throughput | kg/s |
| \(c_p\) | Dough specific heat | J/(kg·K) |
| \(T_1\) | Dough in | K |
| \(T_2\) | Crumb out | K |
| \(b\) | Bake loss (water evaporated) | - |
| \(\dot M_t\) | Tins or band heated | kg/s |
| \(c_t\) | Tin specific heat | J/(kg·K) |
| \(T_t\) | Tin temperature rise | K |
| \(\eta\) | Oven efficiency | - |
| \(\lambda\) | latent heat of water at 100 °C, 2 257 kJ/kg | J/kg |
| \(c_w\) | specific heat of water, 4.1868 kJ/(kg·K) | J/(kg·K) |
| \(LHV\) | Fuel heating value | J/kg |
| \(Q_d\) | Heat to the dough | W |
| \(Q_e\) | Heat to evaporate the bake loss | W |
| \(Q_t\) | Heat to the tins | W |
| \(Q\) | Fuel heat input | W |
| \(\dot m_f\) | Fuel | kg/s |
| \(\dot m_f/\dot M\) | Fuel per tonne of dough | kg/kg |
Method and standards
Useful heat over oven efficiency.
Where it is used
- Oven selection and fuel budgets.
Common mistakes
- Ignoring the bake loss.
- Using LHV efficiency with HHV fuel.
Assumptions and limits
- The dough term heats the whole dough, water included, to the crumb temperature; the bake loss then adds the heat from the crumb temperature to 100 °C and the latent heat, so nothing is counted twice.
References
- Mass and energy balances (definitions); latent heat 2 257 kJ/kg
Questions and answers
Where does the heat go?
About half to evaporating the bake loss; the rest to dough, tins and losses.
What oven efficiency is typical?
35–55 % for direct-fired tunnel ovens.
Why count tins?
Heavy tins heated every cycle can take a quarter of the useful heat.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.