FireCADCalc

Milk Homogeniser Power and Temperature Rise

Hydraulic and motor power of a high-pressure homogeniser and the temperature rise of the product from flow and homogenising pressure.

Food, dairy and textile

Inputs

Examples: Illustrative 10000 L/h at 200 barCream at 150 barUHT milk, 250 bar

Accepted: 3.6 to 3,600,000 L/h
Accepted: 1 to 1,000 bar
Accepted: 800 to 1,300 kg/m³
Accepted: 2 to 4.5 kJ/(kg·K)
Accepted: 30 to 100 %

Results

A homogeniser is a piston pump that forces product through a narrow gap; the hydraulic power is flow × pressure. Almost all of it turns into heat in the product as the fat globules are broken up, so the product warms by Δp/(ρ c_p): about 2.5 K per 100 bar for milk. Motor power adds pump and drive losses. The energy per 1000 L is the motor power divided by the flow.

Hydraulic power55.556kW
Motor power69.444kW
Temperature rise of the product4.9788K
Energy per 1000 L6.9444kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10000 L/h at 200 bar. The inputs, in the units selected above:

InputValue
Product flow10,000 L/h
Total homogenising pressure (both stages)200.00 bar
Product density1,030.0 kg/m³
Product specific heat3.9000 kJ/(kg·K)
Pump and drive efficiency80.000 %

Applying the formula below gives:

ResultValue
Hydraulic power55.556 kW
Motor power69.444 kW
Temperature rise of the product4.9788 K
Energy per 1000 L6.9444 kWh

Open this example in the calculator and change any input.

Formula

\(P_h = \dot V\Delta p, \quad P_m = \frac{P_h}{\eta}, \quad \Delta T = \frac{\Delta p}{\rho c_p}\)

Variables

Symbol Meaning SI unit
\(\dot V\) Product flow m³/s
\(\Delta p\) Total homogenising pressure (both stages) Pa
\(\rho\) Product density kg/m³
\(c_p\) Product specific heat J/(kg·K)
\(\eta\) Pump and drive efficiency -
\(P_h\) Hydraulic power W
\(P_m\) Motor power W
\(\Delta T\) Temperature rise of the product K
\(e\) Energy per 1000 L J

Method and standards

Homogeniser.

Where it is used

  • Dairy, juice and emulsion plants.
  • Motor sizing and heat balance.

Common mistakes

  • Forgetting the temperature rise in the heat balance.
  • Using the first-stage pressure only.

Assumptions and limits

  • All hydraulic power dissipated in the product.

References

  • Hydraulic power of a positive-displacement homogeniser
  • Tetra Pak
  • Dairy Processing Handbook (Tetra Pak Processing Systems, Lund)

Questions and answers

How much does homogenising warm milk?

About 2.5 K per 100 bar: 200 bar raises it by about 5 K.

How big is the motor for 10,000 L/h at 200 bar?

About 69 kW at 80 % efficiency.

What do the defaults represent?

An illustrative 10,000 L/h milk homogeniser at 200 bar total with 80 % efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.