Worked example
Example: Illustrative skim milk UF to VCF 5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed volume | 10.000 m³ |
| Permeate volume removed | 8.0000 m³ |
| Component concentration in the feed | 3.3000 % |
| Rejection of the component | 99.000 % |
| Membrane area | 50.000 m² |
| Processing time | 4.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volume concentration factor | 5.0000 |
| Retentate volume | 2.0000 m³ |
| Retentate concentration | 16.237 % |
| Yield of the component in the retentate | 98.403 % |
| Average permeate concentration | 0.065858 % |
| Average flux | 40.000 L/(m²·h) |
Open this example in the calculator and change any input.
Formula
\(VCF = \frac{V_f}{V_f - V_p}, \quad C_r = C_f VCF^{R}, \quad Y = VCF^{R - 1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_f\) | Feed volume | m³ |
| \(V_p\) | Permeate volume removed | m³ |
| \(C_f\) | Component concentration in the feed | - |
| \(R\) | Rejection of the component | - |
| \(A\) | Membrane area | m² |
| \(t\) | Processing time | s |
| \(VCF\) | Volume concentration factor | - |
| \(V_r\) | Retentate volume | m³ |
| \(C_r\) | Retentate concentration | - |
| \(Y\) | Yield of the component in the retentate | - |
| \(\bar C_p\) | Average permeate concentration | - |
| \(J\) | Average flux | m/s |
Method and standards
VCF.
Where it is used
- Milk and whey ultrafiltration.
- Juice and protein concentration.
Common mistakes
- Using VCF as the concentration ratio for partly passing components.
- Ignoring hold-up volume.
Assumptions and limits
- Constant rejection; batch operation.
References
- Batch concentration with constant rejection
Questions and answers
What VCF do 10 m³ of milk give after removing 8 m³ of permeate?
A VCF of 5; protein at 99 % rejection rises from 3.3 % to about 16.2 %.
Why is the yield below 100 %?
Rejection below one lets some of the component through with the permeate.
What do the defaults represent?
An illustrative batch of 10 m³ of skim milk at 3.3 % protein, 8 m³ of permeate removed through 50 m² in 4 hours, rejection 99 %.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.