FireCADCalc

Continuous Fryer: Water Evaporated, Oil Uptake and Heat

Water evaporated, oil absorbed and heat load of a continuous fryer from product feed, moisture in and out and oil content of the fried product.

Food, dairy and textile

Inputs

Examples: 2 t/h potato slices to chipsFries par-fry

Results

Oil taken up must be replaced by fresh oil; a high turnover keeps the oil fresh.

Fried product2,069.0kg/h
Water evaporated1,055.2kg/h
Oil taken up124.14kg/h
Fryer heat load1,069.9kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 t/h potato slices to chips. The inputs, in the units selected above:

InputValue
Raw product feed2,000.0 kg/h
Moisture in the raw product78.000 %
Moisture in the fried product2.0000 %
Oil in the fried product34.000 %
Product specific heat3.5000 kJ/(kg·K)
Product in15.000 °C
Losses share15.000 %

Applying the formula below gives:

ResultValue
Fried product687.50 kg/h
Water evaporated1,546.2 kg/h
Oil taken up233.75 kg/h
Fryer heat load1,334.9 kW

Open this example in the calculator and change any input.

Formula

\(\dot M_p = \frac{\dot M(1 - w_1)}{1 - w_2 - o_2}, \quad \dot E = \dot M w_1 - \dot M_p w_2, \quad Q = \frac{\dot M c_p(100\,°C - T_1) + \dot E\lambda}{1 - \varepsilon}\)

Variables

Symbol Meaning SI unit
\(\dot M\) Raw product feed kg/s
\(w_1\) Moisture in the raw product -
\(w_2\) Moisture in the fried product -
\(o_2\) Oil in the fried product -
\(c_p\) Product specific heat J/(kg·K)
\(T_1\) Product in K
\(\varepsilon\) Losses share -
\(\dot M_p\) Fried product kg/s
\(\dot E\) Water evaporated kg/s
\(\dot M_o\) Oil taken up kg/s
\(Q\) Fryer heat load W

Method and standards

Solids, water and oil balances.

Where it is used

  • Fryer sizing and heater duty.

Common mistakes

  • Ignoring oil uptake in the product mass.
  • Using wet-basis moisture as dry-basis.

Assumptions and limits

  • Product heated to 100 °C; λ at 100 °C.
  • Not included: heating the fresh make-up oil from storage to frying temperature, and heating low-moisture products (crisps) above 100 °C towards the oil temperature. For such products the load is underestimated; add these terms or raise the losses share.

References

  • Mass and energy balances (definitions); latent heat of water 2 257 kJ/kg at 100 °C

Questions and answers

Why does oil uptake matter?

It is the fresh oil the fryer consumes and sets oil turnover.

Where does the heat go?

Mostly to evaporate water; heating the product to 100 °C is a small part.

How is the fryer heated?

Usually thermic fluid or direct-fired heat exchangers.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators