Worked example
Example: 300 t/d at 240 °C, 1 % steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil flow | 300.00 t/d |
| Stripping steam on oil | 1.0000 % |
| Oil specific heat | 2.2000 kJ/(kg·K) |
| Oil in | 80.000 °C |
| Deodorising temperature | 240.00 °C |
| Heat recovered by oil–oil exchange | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stripping steam | 125.00 kg/h |
| Heat to reach deodorising temperature | 1,222.2 kW |
| Net heating after recovery | 488.89 kW |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = s\dot M, \quad Q = \dot Mc_p(T_2 - T_1), \quad Q_n = Q(1 - \eta_r)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot M\) | Oil flow | kg/s |
| \(s\) | Stripping steam on oil | - |
| \(c_p\) | Oil specific heat | J/(kg·K) |
| \(T_1\) | Oil in | K |
| \(T_2\) | Deodorising temperature | K |
| \(\eta_r\) | Heat recovered by oil–oil exchange | - |
| \(\dot m_s\) | Stripping steam | kg/s |
| \(Q\) | Heat to reach deodorising temperature | W |
| \(Q_n\) | Net heating after recovery | W |
Method and standards
Sensible heat and steam rate.
Where it is used
- Refinery utility sizing.
Common mistakes
- Ignoring vacuum ejector steam (often larger than stripping steam).
Assumptions and limits
- No losses.
- Only the stripping steam is counted. Motive steam for the vacuum ejectors, often larger than the stripping steam, and heat losses are not included.
References
- Definitions and mass and energy balances
Questions and answers
How much stripping steam?
0.5–1.5 % of oil for deodorising; 1–3 % for physical refining of high-FFA oils.
Why such high temperature?
Odour compounds and FFA must be volatile enough to strip under vacuum.
Why recover heat?
Hot deodorised oil can preheat the incoming oil, saving 50–80 % of the heating.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.