Oil Hydrogenation: Hydrogen per Iodine Value Drop

Hydrogen to lower the iodine value of an oil by a given amount (1 mol H₂ per mol I₂), its normal volume, and the hydrogen per tonne of oil.

Food, dairy and textile

Inputs

Examples: 20 t soybean oil IV 130 → 75Light brush IV 110 → 95

Results

One unit of iodine value needs about 0.08 kg of hydrogen (0.88 Nm³) per tonne of oil.

Hydrogen91.742kg
Hydrogen volume at 0 °C, 1 atm1,020.0m³
Hydrogen per tonne of oil4.5871kg/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 t soybean oil IV 130 → 75. The inputs, in the units selected above:

InputValue
Oil20,000 kg
Iodine value before130.00 -
Iodine value after75.000 -
Hydrogen losses (purge, dissolved)5.0000 %

Applying the formula below gives:

ResultValue
Hydrogen91.742 kg
Hydrogen volume at 0 °C, 1 atm1,020.0 m³
Hydrogen per tonne of oil4.5871 kg/t

Open this example in the calculator and change any input.

Formula

\(n = \frac{M(IV_1 - IV_2)}{100\,M_{I_2}}, \quad m_{H_2} = nM_{H_2}(1 + x)\)

Variables

Symbol Meaning SI unit
\(M\) Oil kg
\(IV_1\) Iodine value before -
\(IV_2\) Iodine value after -
\(x\) Hydrogen losses (purge, dissolved) -
\(m_{H_2}\) Hydrogen kg
\(V_{H_2}\) Hydrogen volume at 0 °C, 1 atm m³
\(m_{H_2}/M\) Hydrogen per tonne of oil kg/kg

Method and standards

Iodine value stoichiometry.

Where it is used

  • Hydrogenation plant hydrogen budgets.

Common mistakes

  • Using wrong IV units.
  • Forgetting purge losses.

Assumptions and limits

  • Ideal gas at 0 °C, 1 atm for volume.

References

  • Definitions and mass and energy balances: iodine value = g I₂ per 100 g oil; one H₂ saturates the double bond that adds one I₂

Questions and answers

Where does 0.08 kg/t per IV come from?

1 g I₂ per 100 g oil = 10 kg I₂ per tonne; × 2.016/253.8 = 0.079 kg H₂.

Why add losses?

Purge, dissolved hydrogen and leaks; 5–10 % is usual.

Does IV fall linearly with hydrogen?

Yes, by definition; selectivity decides which fatty acids are saturated.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.