Worked example
Example: 2 t/h potato slices to chips. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Raw product feed | 2,000.0 kg/h |
| Moisture in the raw product | 78.000 % |
| Moisture in the fried product | 2.0000 % |
| Oil in the fried product | 34.000 % |
| Product specific heat | 3.5000 kJ/(kg·K) |
| Product in | 15.000 °C |
| Losses share | 15.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fried product | 687.50 kg/h |
| Water evaporated | 1,546.2 kg/h |
| Oil taken up | 233.75 kg/h |
| Fryer heat load | 1,334.9 kW |
Open this example in the calculator and change any input.
Formula
\(\dot M_p = \frac{\dot M(1 - w_1)}{1 - w_2 - o_2}, \quad \dot E = \dot M w_1 - \dot M_p w_2, \quad Q = \frac{\dot M c_p(100\,°C - T_1) + \dot E\lambda}{1 - \varepsilon}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot M\) | Raw product feed | kg/s |
| \(w_1\) | Moisture in the raw product | - |
| \(w_2\) | Moisture in the fried product | - |
| \(o_2\) | Oil in the fried product | - |
| \(c_p\) | Product specific heat | J/(kg·K) |
| \(T_1\) | Product in | K |
| \(\varepsilon\) | Losses share | - |
| \(\dot M_p\) | Fried product | kg/s |
| \(\dot E\) | Water evaporated | kg/s |
| \(\dot M_o\) | Oil taken up | kg/s |
| \(Q\) | Fryer heat load | W |
Method and standards
Solids, water and oil balances.
Where it is used
- Fryer sizing and heater duty.
Common mistakes
- Ignoring oil uptake in the product mass.
- Using wet-basis moisture as dry-basis.
Assumptions and limits
- Product heated to 100 °C; λ at 100 °C.
- Not included: heating the fresh make-up oil from storage to frying temperature, and heating low-moisture products (crisps) above 100 °C towards the oil temperature. For such products the load is underestimated; add these terms or raise the losses share.
References
- Mass and energy balances (definitions); latent heat of water 2 257 kJ/kg at 100 °C
Questions and answers
Why does oil uptake matter?
It is the fresh oil the fryer consumes and sets oil turnover.
Where does the heat go?
Mostly to evaporate water; heating the product to 100 °C is a small part.
How is the fryer heated?
Usually thermic fluid or direct-fired heat exchangers.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.