FireCADCalc

Beverage Carbonation: CO₂ Volumes from Pressure and Temperature

Dissolved CO₂ in water at equilibrium as volumes (at 0 °C, 1 atm) and g/L from the CO₂ partial pressure and temperature, with Henry's constant from IAPWS G7-04.

Distillery and ethanolFood, dairy and textile

Inputs

Examples: 3.5 bar CO2 at 4 °CBeer 1.6 bar at 2 °C

Absolute: add the atmospheric pressure (about 1.01 bar) to a gauge headspace reading.

Results

IAPWS notes G7-04 is not meant for precise work near ambient temperature; treat results as ±5 %. Water only: sugar and alcohol lower solubility.

Henry's constant81.781MPa
Mole fraction of CO₂ in the liquid1,956.4ppm
CO₂ volumes (0 °C, 1 atm, per volume of water)2.4222
CO₂ concentration4.7888g/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3.5 bar CO2 at 4 °C. The inputs, in the units selected above:

InputValue
CO₂ partial pressure (absolute)3.5000 bar
Temperature4.0000 °C

Applying the formula below gives:

ResultValue
Henry's constant87.812 MPa
Mole fraction of CO₂ in the liquid3,985.8 ppm
CO₂ volumes (0 °C, 1 atm, per volume of water)4.9448
CO₂ concentration9.7758 g/L

Open this example in the calculator and change any input.

Formula

\(x = \frac{p_{CO_2}}{k_H(T)}, \quad c = \frac{x}{1 - x}\cdot\frac{\rho_w}{M_w}\cdot M_{CO_2}, \quad V_{CO_2} = \frac{c}{\rho_{CO_2,0}}\)

Variables

Symbol Meaning SI unit
\(p_{CO_2}\) CO₂ partial pressure (absolute) Pa
\(T\) Temperature K
\(k_H\) Henry's constant Pa
\(x\) Mole fraction of CO₂ in the liquid -
\(V_{CO_2}\) CO₂ volumes (0 °C, 1 atm, per volume of water) -
\(c\) CO₂ concentration kg/m³
\(\rho_w\) Water density, taken as 1 kg/L kg/m³
\(M_w\), \(M_{CO_2}\) Molar masses of water (18.015) and CO₂ (44.009) kg/kmol
\(\rho_{CO_2,0}\) Density of CO₂ gas at 0 °C and 1 atm, 1.977 kg/m³

Method and standards

Henry's law with IAPWS G7-04.

Where it is used

  • Carbonator settings.
  • Bottling quality checks.

Common mistakes

  • Using gauge pressure.
  • Applying to sugary or alcoholic liquids without correction.

Assumptions and limits

  • Pure water; equilibrium.
  • The CO₂ pressure is absolute: a gauge headspace reading needs the atmospheric pressure added (otherwise the volumes are about 1.4 low at 4 °C).
  • Volumes are on the real-gas basis the brewing and soft-drink industries use: CO₂ at 0 °C and 1 atm weighs 1.977 g/L (about 22.26 L/mol, against 22.414 for an ideal gas), so 1 volume = 1.977 g/L.

References

  • IAPWS G7-04 (2004): Henry's constant of CO₂ in water
  • Volumes at 0 °C and 101.325 kPa (22.414 L/mol); water density taken as 1 kg/L

Questions and answers

What is a 'volume' of CO₂?

The volume of CO₂ gas at 0 °C and 1 atm dissolved per volume of liquid, taking real CO₂ at 1.977 g/L, so 1 volume is 1.977 g/L.

What levels are usual?

Beer 2.2–2.8 volumes, colas 3.5–4, sparkling water up to 5.

Why chill to carbonate?

Henry's constant rises with temperature: cold water holds much more CO₂ at the same pressure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators